This mode is not supported.
AUTOMATIC
Mode
In cooling mode the room air is cooled to the preset target temperature.
The desired room temperature is set in 1 °C steps using the /
buttons. If the room temperature reaches 1 °C above the set target
temperature, the indoor unit starts to cool the room air. If the actual
temperature falls approx. 0.5 °C below the set room temperature, the
controller switches the cooling off. In order to protect the compressor, the
controller will only switch the cooling back on after a holding period of 3
minutes.
COOLING Mode
COOLING
MODE
MODE
In circulation mode only the room air is circulated.
The room temperature cannot be changed in this mode
Cooling is not activated
CIRCULATION Mode
Circulation
MODE
This mode is not supported.
HEATING
Mode