beautypg.com

Unit description transportation and packaging, Combinations – REMKO ATY 261 User Manual

Page 5

background image

The equipment has been shipped
in sturdy packaging. Immediately
check the equipment on delivery
and make a note of any damage or
missing parts on the delivery note.
Inform the forwarding agent and
contractual partner.

Warranty claims at a later date will
not be accepted.

Unit description

Transportation and
packaging

The indoor unit of the combined
split-design air conditioning
equipment absorbs the heat
extracted from the interior room
being cooled. The outdoor
component then expels this heat
into the outside air.

The unit is designed for indoor
installation, high up on walls. It is
operated by an infrared remote
control.

The indoor unit comprises a finned
vaporiser, vaporiser fan, controller
and condensation tray. The indoor
unit may be used in conjunction
with REMKO outdoor components
that provide the required cooling
output. The outdoor component is
controlled by the regulator in the
indoor unit.

Condensation pumps are also
available as accessories.

Schematic of refrigerant circuit

Vaporiser fan

Connection to suction pipe

Connection to injection pipe

Vaporiser

Refrigerant pipes are used to connect the indoor unit to the outdoor
component.

Outdoor unit

System layout

Stop valve

Indoor unit

Liquefier fan

Injection pipe

Suction pipe

Indoor area

Outdoor area

Control cable

Mains cable

Condensation pipe

Combinations

ATY 261

ATY 351

RXM 226

••

RXM 235

••

RXM 326

••

RXM 335

•••

RXM 426

••••

RXM 435

••••

Cooling

5

This manual is related to the following products: