Type of task
Check / Maintenance / Inspection
Commissioning
Monthly
Six-monthly
Yearly
General
•
•
Measure voltage and current
•
•
Check fan is functioning correctly
•
•
Dirt on vaporiser
•
•
Check condensation drain
•
•
Test insulation
•
•
Check moving parts
•
•
Cleaning the condensation
pump (accessory)
The indoor unit may include a
built-in or separate condensation
pump for pumping the
condensation to a drain at a higher
level.
Observe the care and maintenance
instructions specified in the
separate manual.
1 O
pen front cover
5 Cleaning with lukewarm water
3. Press up the flaps on the filter
and pull it down and out by the
flaps (Fig 3).
4. Clean the filter using a normal
vacuum cleaner. The dirty side
should be face up(Fig. 4).
5. Clean off any dirt using
lukewarm water and mild
cleaning agents. The dirty side
should be face down(Fig. 5).
6. If water is used, let the filter
dry out properly in air before
replacing it in the unit.
7. Carefully insert the filter. Ensure
it locates correctly.
8. Close the lower display cover
in the opposite order to that
described above.
9. Set the desired operating mode.
3
Pull out the filter
4 Clean with a vacuum cleaner
2
Remove the display cover
15