beautypg.com

REMKO BL 262 DC User Manual

Page 9

background image

Data specific to indoor unit

BL 262 DC IT

BL 352 DC IT

Application area (room volume), approx.

m

3

80

110

Adjustment range, room temperature

°C

+17 to +30, +8 with "FP" function

Operating range

°C

+17 to +32

Air flow volume per level

m³/h

360/480/550

370/480/630

Sound pressure level per speed setting

5)

dB (A)

28/36/40

27/36/42

Sound pressure level, Silent/Turbo mode

5)

dB (A)

22/42

22/44

Sound power level max.

5)

dB(A)

53

56

Enclosure class

IP

X 0

Condensate drainage connection

mm

18

Dimensions: H/W/D

mm

280/750/198

280/835/198

Weight

kg

7.0

8.5

EDP no.

1629264

1629354

5)

At distance of 1m in the open air; specified values are maximum values

Data specific to outdoor unit

BL 262 DC AT

BL 352 DC AT

Power supply

V/Ph/

Hz

230 / 1~ / 50

Operating range, cooling

°C

+5 to +50

Operating range, heating

7)

°C

+5 to +34

Air flow rate, max.

m³/h

1,800

2,000

Enclosure class

IP

24

Sound power level max.

5)

dB (A)

60

63

Sound pressure level

5)

dB (A)

49

55

Refrigerant

6)

R 410A

Refrigerant, basic capacity

kg

1.1

1.1

Max. operating pressure

kPa

4,200 / 1,500

Refrigerant piping, max. length

m

3, 5, 8

3, 5, 8

Refrigerant piping, max. height

m

5

5

Dimensions: H/W/D

mm

590/760/285

Weight

kg

35.0

35.5

EDP no.

1629263

1629353

5)

At distance of 1m in the open air; specified values are maximum values

6)

Contains greenhouse gas according to Kyoto protocol, GWP 1975

7)

This can be extended to -15°C with the appropriate accessory kit

9

This manual is related to the following products: