beautypg.com

4 selection of installation location – REMKO BL 262 DC User Manual

Page 23

background image

5.4 Selection of installation

location

Indoor unit

The indoor unit is designed for horizontal wall

installation above doors. However, it can also be

used in the upper wall area (min. 1.75m above the

floor).

Outdoor unit

The outdoor unit is designed for horizontal installa-

tion on a base in outdoor areas. The installation

site must be level, flat and firm. The unit should

also be secured to prevent it from tipping over. The

outdoor unit can be set up outside as well as inside

a building. For external installation, please observe

the following notes to protect the unit from the

influence of the weather.

Rain

For floor or roof set-up, the unit should be installed

with at least 10cm ground clearance. A floor

bracket is available as an optional accessory.

Sun

The condenser on the outdoor unit emits heat.

Exposure to sunlight further increases the temper-

ature of the fins and reduces the heat released by

the finned heat exchanger. The outdoor unit should

be installed on to the north side of the building

whenever possible. If necessary, take measures to

provide sufficient shade (responsibility of cus-

tomer). One possible solution is to build a small

roofed area over the unit. These measures should

not affect the flow of warm outlet air.

Wind

If the unit is being installed in windy areas, ensure

that the warm outlet air is discharged in the pre-

vailing wind direction. If this is not the possible, it

may be necessary to install a windbreak (to be pro-

vided by the customer). Ensure that the windbreak

does not adversely affect the air intake to the unit.

1

Fig. 24: Windbreak

1: Wind

Snow

The unit should be wall-mounted in areas of heavy

snowfall. Installation should be at least 20cm

above the expected level of snow to prevent snow

from entering the outdoor unit. An optional wall

bracket is available as an accessory.

20 cm

1

Fig. 25: Minimum clearance to snow

1: Snow

Installation inside buildings

n

Ensure that heat can dissipate adequately

when placing the outdoor unit in cellars, lofts,

adjoining rooms or halls (Fig. 26).

n

Install an additional fan with a rated flow com-

parative to that of the outdoor unit being

installed in the room and which can compen-

sate any additional pressure loss in ventilation

ducts (Fig. 26).

n

Comply with any regulations and conditions

affecting the statics of the building. If neces-

sary, fit acoustic installation.

23

This manual is related to the following products: