beautypg.com

Remko bl...dc – REMKO BL 262 DC User Manual

Page 46

background image

Error P2: High temperature protection of compressor top

Check if the air flow system of indoor and out-

door units are obstructed?

YES

Clear up the air inlet and outlet or the heat

exchanger of indoor and outdoor units.

NO

Turn off the power supply and turn it on 10

minutes later.

YES

Check if the unit can start normally

NO

Check if all the connection, especially the con-

nection of OLP (Over Load Protector) sensor is

good.

YES

Refrigerant system is blocked, such as capillary

or weled point of pipes.

Error P3: Compressor drive error

Check all the wires between control PCB,

module PCB and compressor.

NO

Correct the connections.

YES

IPM continuity check. Check if the IPM terminal

resistance values are uniform.

NO

Replace the compressor.