6.3 Connection of

quick-release couplings

The refrigerant pipes should be connected by the

customer on the right-hand side of the outdoor

component. The pre-filled refrigerant piping are

connected to the outdoor component by means of

the quick-connector system. Once installed, the

connections should be insulated to make them

vapour diffusion proof. The following instructions

describe the installation of the refrigerant piping for

the indoor unit on the outdoor unit.

1.

Remove the pre-installed plastic cover from

the outdoor component (Fig. 32).

Fig. 32: Remove the plastic cover

2.

Remove the green/black protective caps from

the quick-connectors on the outdoor compo-

nent, as well as the flexible refrigerant pipes

on the indoor unit (Fig. 33 and Fig. 34).

Fig. 33: Remove protective caps

Fig. 34: Remove protective caps

3.

Before connecting the refrigerant pipes,

ensure that the quick-release couplings are

situated in front of one another (Fig. 35).

Fig. 35: Position of the quick-release couplings

4.

First connect and hand-tighten the refrigerant

piping to ensure it is correctly seated.

5.

Then install the suction pipe with the largest

diameter (Fig. 36).

NOTICE!

When connecting the refrigerant piping,

take note of the "Outdoor unit, top" and

"Outdoor unit bottom" labelling and not

the colour-coding of the sealing caps.

Note the diameter of the lines. In order to

guarantee the function of the unit, the line

must be connected with other lines of

identical diameter!