VCM-X Component & Systems Wiring
Modular & Non-Modular VAV/Zone Controller Wiring
61
Non-Modular VAV/Zone Controller Actuator Package Wiring
Figure 40: OE742-32 & OE744-32 - Non-Modular Zone Controller Actuator Package - P.I. & P.D. Wiring
FILENAME
DATE:
S. Olson
DESCRIPTION:
PAGE
JOB NAME
ZCAP-NM-Main-Wire-1A.CDR
1 of 7
01/16/13
T
SHLD
R
24 VAC
GND
www.orioncontrols.com
OE744-32-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
WattMaster Label
#LB102042-06
Rev. 01A
1
0
OE282
TB3
STAT
GND
24VAC
R
SHLD
T
TB2
REC
24 VAC Transformer. Size As
Required For Number Of
Controllers Connected. Each
VAV/Zone Controller Actuator
Package Requires 6 VA Minimum.
Wire To Previous And/Or Next VAV/Zone
Controller Actuator Package Or Device On The
Local Communications Loop Using 2 Conductor
Twisted Pair With Shield Cable Available From
WattMaster. All Communication Cable Used
Must Be Belden 82760 Or Its Equivalent.
Line
Voltage
GND
24VAC
WARNING:
When Multiple VAV/Zone Controller
Actuator Packages Are Powered
From A Single Transformer Polarity
Must Be Observed Or Damage To
The Controllers Will Result.
OE742-32 & OE744-32 VAV/Zone Controller
Wiring Details
Actuator Package
Connector Not Used
With This Product
Damper Actuator
Damper Actuator Cable
OE325-01 Fan & Reheat
Expansion Module
(See Reheat Board Wiring For
Detailed Wiring Connections)
Connect FRP Tubing (By Others) To Terminal
Unit Air Flow Pickup Tube Hi & Lo Ports
(P.I. VAV/Zone Controller Packages Only)
This Expansion Module Is
Only Required For Single
Duct Terminal Units With
Reheat And All Fan
Terminal Units
Modular Expansion Cable
Supplied With OE325-01 Expansion Module
TSDRSC Or FMRSC Cable As
Required. Select Cable
Depending On Sensor(s) Used.
See Notes Above For Details
Optional - Supply Air Temperature
Sensor. Only Required When The
Orion VCM-X Controller Is Not
Installed On The HVAC Unit
Connected To The Terminal Units.
Locate In Ductwork Downstream
Of The Terminal Unit
ZON
E
EXPAN
S
IO
N
YS
1
0
2
2
52
R
E
V
1
WAT
M
ASTER
C
ONT
R
OLS
IN
C
.
M
A
DE
IN
USA
Rc
R1
R2
R3
R4
A
OUT
GND
RELAYS
ANALOG
OUTP
U
T
STAT
THERM
4-20mA
0-10V
0-5V
GND
AI
N
ANALOG
INPUT
VREF
EXPANSION IN
PWR
PI
C
1
8F
4
5
2
0
10A250V
A
C
~
5A
30VD
C
SA
VDE
G5Q-1A4
OMRON
DC24V
CH
IN
A
10A250V
A
C
~
5A
30VD
C
SA
VDE
G5Q-1A4
OMRON
DC24V
CH
IN
A
10A250V
A
C
~
5A
30VD
C
SA
VDE
G5Q-1A4
OMRON
DC24V
CH
IN
A
10A250V
A
C
~
5A
30VD
C
SA
VDE
G5Q-1A4
OMRON
DC24V
CH
IN
A
COMM
OE210-02, OE211-02, OE212-02
Or OE213-02 Modular Room Sensor
Display
Override
OVERRIDE
ALARM
OE217-00 / OE217-01
Digital Room Sensor
Wiring When Using A Modular Sensor
Wiring When Using A Digital Room Sensor
FMRSC Cable
TSDRSC Cable
Note: The Total Length Of Cable
Cannot Exceed 160 Feet.
Note: The Total Length Of Cable
Cannot Exceed 160 Feet.