Networked single loop system, Vcm-x component & systems wiring 24, Zone – Orion System VCM-X E-BUS Component User Manual
Page 24
Zone
Zone
Networked Single Loop System
VCM-X Component & Systems Wiring
24
1
10 V
AC T
o
24 V
A
C
Power Pack
Note:
CommLink Must Be
Set For Multiple Loop
Operation When Used With
A
MiniLink Whether It Is
A
Single Loop System Or Not.
If it Doesn’t Have
A
MiniLink
Set It
T
o
Single Loop.
T
ypical Single Loop Networked System W
ith CommLink 5 Only
O-VCMX-Network-SingleLoop1A.CDR
VCM-X E-BUS Networked System - Single Loop
FILENAME
DESCRIPTION:
P
AGE
Wiring & Connection Diagrams
JOB NAME
1 of 5
TB1
Connect
T
o
Modular
I/O Connectors
Located On Back
Of
The System Manager
Connect MIni Din Connector
Cable Ends
T
o
Female
Connectors on Modular
Service
T
ool
And VCM-X
E-BUS Controller
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
ST
A
T
US
SE
TPOINTS
SCHEDULES
AL
ARMS
OVERRIDES
Line V
oltage
Modular System
Manager SD
System Manager TS II
24 V
A
C
(6 V
A
)
T
o
Next HV
AC Unit
Controller On Loop
Up T
o
60 Controllers
Can Be Interconnected
Line V
oltage
Line V
oltage
Line V
oltage
Line V
oltage
VCM-X E-BUS Unit Controller
VCM-X E-BUS Unit Controller
VCM-X E-BUS Unit Controller
VCM-X E-BUS Unit Controller
24 V
A
C
(8 V
A
)
24 V
A
C
(8 V
A
)
24 V
A
C
(8 V
A
)
24 V
A
C
(8 V
A
)
SHLD
T
R
T
ypical T
erminal Blocks.
All
W
iring T
o
Be T T
o
T
, SHLD (G)
T
o
SHLD (G) & R T
o
R
T
G
R
485 LOOP
WARNING
OBSERVE
POLARITY
WARNING
OBSERVE
POLARITY
WARNING
OBSERVE
POLARITY
WARNING
OBSERVE
POLARITY
Note:
Either
A
Modular System
Manager SD, System Manager
TS II,
Modular Service
T
ool SD Or PC With
Prism 2 Software Installed Can Be
Used
T
o
Program
And Configure
The
Orion System. For Computer
And
Remote Connection Information, See
The Computer Connection Section Of
This Manual.
Note:
The System Manager
TS II Wiring
Is
T
ypical For
All System
T
ypes
And
Configurations. It Is Shown On
This Page
Only
T
o
Conserve Space.
RS
T
+
BLACK (R)
Connect T
o
T
, R & S
T
erminals On
VCM-X Or
V
A
V/Zone
Controller
RED (24 VAC)
BROWN (GND)
WHITE (T)
BARE (S)
.1uF
YS102178 R4
WQVGA
Graphical Interface
W
a
ttMaster Controls, Inc
C24
R9
R7
R6
R5
R2
R1
C51
C39
C20
C19
C15
C14
C13
C12
C11
C10
C9
C7
C1
X3
8.
00
Mh
z
OFF
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
1002
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
.1uF
1002
.1uF
1002
1002
.1uF
.1uF
.1uF
.1uF
L
TC3824
1002
1002
1002
1002
1002
1002
66.000Mhz
MADE IN USA
330uF 50V
330uF
1002
SERIAL
#
OPT
4
OPT
3
OPT
2
OPT
1
TERM
RT
C
YS102178 R4
WQVGA
Graphical Interface
W
a
ttMaster Controls, Inc
CAL
5V
3.3V
2.5V
J3
R34
R16
R13
R8
R39
X2
R26
R17
R14
C24
U13
R49
R48
R47R46
R45
R44
R43
R40
R37
R35
R32
R31
R29
R27
R24
R22
R12
R1
1
R10
R9
R7
R6
R5
R2
R1
L5
L4
D12
D11
D1
C51
C50
C45
C41
C39
C36
C20
C19
C18
C17
C16
C15
C14
C13
C12
C11
C10
C9
C8
C7
C6
C5
C4
C1
J1
R41
C23
C25
C26
R42
X3
R20
C27
C34
C
40
U10
U1
1
C28
C29
R18
C35
D2
L1
R25
C31
R19
U9
R28
C32
R30
R33
C30
R15
Q2
R21
R23
SW1
C2
C3
V1
R36
1002
RS
T
+
1002
R
T
5V
GND
TERM
For
All
Applications With
CommLink(s) Or MiniLink(s),
Both Jumpers Must Be OFF
.
WHITE (T)
DRAIN WIRE (SHLD)
BLACK (R)
RED (24 V
AC)
Line V
oltage
24 V
A
C
(6 V
A
)
CLEAR (GND)
GREEN (GND)
Back V
iew
Front V
iew
CommLink 5
Serial #
COMPUTER
USB
10/100
ETHERNET
DIAG
485 LOOP
POWER
ACT
LNK
HIGH
LOW
BAUD
R(+)
24V
GND
SHLD
T(
-)
MULT
IPLE
SINGLE
LOOP
BY
:
S. Olson
DA
TE:
Modular Service
T
ool SD
05/12/15
Figure 5: Networked Single Loop System With CommLink Only Wiring