Networked single loop system, Vcm-x component & systems wiring 26, Zone – Orion System VCM-X E-BUS Component User Manual
Page 26

Zone
Zone
Networked Single Loop System
VCM-X Component & Systems Wiring
26
EPROM
U3
U5
RAM
CX
2
1
U2
R1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILIPS
D1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D4
GN
D
24VA
C
TB1
D5
C1
1
U12
LED 2
POWER
V1
R25
R26
C7
CX
15
CX13
PROC.
DRIVER
LOOP
DRIVER
LOCAL
LOOP
GN
D
AIN
2
AIN 1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN1
0-10V
4-20mA
THERM
TB3
U15
LD5
LD6
U13
C8
LED 1
RV
1
R4
VR
EF
CX
2
U1
1
YS101900PMINILINK
POLLING
DEVICE
REV
. 1
OFF
1
2
4
8
16
32
CX
14
NETWORK
DRIVER
RN3
SHLD
SHLD
T
T
TB4
R
R
U14
NETWORK
LOOP
P5
AD
D
P3
R24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
CX
6
CX
1
U7
U1
X1
C3
C1
R3
CX7
Local
Local
24 V
A
C
(6 V
A
)
MiniLink PD
Note:
Multiple V
A
V/Zone Controllers Can Be Connected
T
o
A
Single
T
ransformer If Desired. However Polarity
Must Be Observed Or Damage
T
o
The Controller(s) Will
Result. See
The Non- Modular
T
ransformer Sizing Page
In
This Manual For
T
ransformer Sizing
And Circuit
Design Information.
Connect
T
o
Next
V
A
V/Zone Controller
On Local Loop
SHLD
T
R
T
ypical T
erminal Blocks.
All
W
iring T
o
Be T T
o
T
, SHLD (G)
T
o
SHLD (G) & R T
o
R
T
G
R
485 LOOP
FILENAME
DESCRIPTION:
P
AGE
Wiring & Connection Diagrams
JOB NAME
3 of 5
T
ypical Single Loop Networked System
W
ith MiniLink Polling Device & Non-Modular V
A
V/Zone Controllers
Line V
oltage
Line
V
oltage
Line
V
oltage
Line
V
oltage
VCM-X E-BUS
Unit Controller
24 V
A
C
(8 V
A
)
24 V
A
C
(6 V
A
)
24 V
A
C
(6 V
A
)
24 V
A
C
(6 V
A
)
WARNING
OBSERVE
POLARITY
O-VCMX-Network-SingleLoop1A.CDR
VCM-X E-BUS Networked System - Single Loop
T
SHLD
R
24 VAC
GND
www.orioncontrols.com
OE744-32-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
1
0
OE282
TB3
STAT
GND
24VAC
R
SHLD
T
TB2
REC
T
SHLD
R
24 VAC
GND
www.orioncontrols.com
OE744-32-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
1
0
OE282
TB3
STAT
GND
24VAC
R
SHLD
T
TB2
REC
T
SHLD
R
24 VAC
GND
www.orioncontrols.com
OE744-32-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
1
0
OE282
TB3
STAT
GND
24VAC
R
SHLD
T
TB2
REC
T
SHLD
R
24 VAC
GND
www.orioncontrols.com
OE744-32-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
1
0
OE282
TB3
STAT
GND
24VAC
R
SHLD
T
TB2
REC
Connect
T
o
Modular
I/O Connectors
Located On Back
Of
The System Manager
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
ST
A
TUS
SE
TPOINTS
SCHEDULES
AL
ARMS
OVERRIDES
WHITE (T)
DRAIN WIRE (SHLD)
BLACK (R)
RED (24 V
AC)
Line V
oltage
24 V
A
C
(6 V
A
)
CLEAR (GND)
GREEN (GND)
Line
V
oltage
24 V
A
C
(6 V
A
)
Note:
Either
A
Modular System Manager SD,
System Manager
TS II, Modular Service
T
ool
SD Or PC With Prism 2 Software Installed Can
Be Used
T
o
Program
And Configure
The Orion
System. For Computer
And Remote
Connection Information, See
The Computer
Connection Section Of
This Manual.
Note:
Multiple V
A
V/Zone
Controllers Can Be Connected
T
o
A
Single
T
ransformer If Desired.
However Polarity Must Be
Observed Or Damage
T
o
The
Controller(s) Will Result. See
The
Non-Modular
T
ransformer Sizing
Page In
This Manual For
T
ransformer Sizing
And Circuit
Design Information.
V
A
V/Zone
Controller
(Non-Modular)
V
A
V/Zone
Controller
(Non-Modular)
V
A
V/Zone
Controller
(Non-Modular)
V
A
V/Zone
Controller
(Non-Modular)
Note:
For System
Manager
TS II Wiring,
See Figure 3.
BY
:
S. Olson
DA
TE:
System Manager TS II
Modular Service
T
ool SD
05/12/15
Modular System Manager SD
Figure 7: Networked Single Loop System With MiniLink PD And Non Modular VAV/Zone Controllers Wiring