Networked single loop system, Vcm-x component & systems wiring, Gn d ain 2 ain 1 +5v tb2 – Orion System VCM-X E-BUS Component User Manual
Page 25: Cx 14 network driver rn3, Enter clear esc prev next down up, Minus, St a tus se tpoints schedules al arms overrides

VCM-X Component & Systems Wiring
Networked Single Loop System
25
Note:
Either
A
Modular System Manager SD,
System Manager
TS II, Modular Service
T
ool
SD Or PC With Prism 2 Software Installed Can
Be Used
T
o
Program
And Configure
The Orion
System. For Computer
And Remote
Connection Information, See
The Computer
Connection Section Of
This Manual.
EPROM
U3
U5
RAM
CX
2
1
U2
R1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILIPS
D1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D4
GN
D
24VA
C
TB1
D5
C1
1
U12
LED 2
POWER
V1
R25
R26
C7
CX15
CX13
PROC.
DRIVER
LOOP
DRIVER
LOCAL
LOOP
GN
D
AIN
2
AIN
1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN1
0-10V
4-20mA
THERM
TB3
U15
LD5
LD6
U13
C8
LED 1
RV
1
R4
VR
EF
CX
2
U1
1
YS101900PMINILINK
POLLING
DEVICE
REV
. 1
OFF
1
2
4
8
16
32
CX
14
NETWORK
DRIVER
RN3
SHLD
SH
LD
T
T
TB4
R
R
U14
NETWORK
LOOP
P5
ADD
P3
R24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
CX
6
CX
1
U7
U1
X1
C3
C1
R3
CX7
Local
Local
24 V
A
C
(6 V
A
)
MiniLink PD
Connect T
o
Other V
A
V/Zone
Controllers
On Loop
Connect T
o
Other V
A
V/Zone
Controllers
On Loop
Connect T
o
Other V
A
V/Zone
Controllers
On Loop
Power/Comm
Board
Power/Comm
Board
V
A
V/Zone
Controller
(Modular)
V
A
V/Zone
Controller
(Modular)
V
A
V/Zone
Controller
(Modular)
Line V
oltage
Line V
oltage
24 V
AC - Size
T
ransformer
For Required V
A
Load
24 V
AC - Size
T
ransformer
For Required V
A
Load
Connect
T
o
Modular
I/O Connectors
Located On Back
Of
The System Manager
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
ST
A
TUS
SE
TPOINTS
SCHEDULES
AL
ARMS
OVERRIDES
Note:
A
Maximum Of 6 V
A
V/Zone Controllers Can Be
Connected
T
o
Each Branch Circuit.
A
total Of 16
Controllers
Are
Allowed Per Power/Comm Board. Use
Additional Power/Comm Boards For Systems
That
Exceed 16 Controllers. See
The V
A
V/Zone Controller
Wiring Diagram For Power/Comm Board
T
ransformer
Sizing
And Circuit Design Information.
TB2
TB2
VAC
VAC
F1
F1
25
25
4A
4A
24
24
SHLD
SHLD
T
T
R
R
POWER
POWER
LD1
LD1
TB1
TB1
C1
C1
POWER & COMM
DIST. BOARD
YS101856
REV. 0
POWER & COMM
DIST. BOARD
YS101856
REV. 0
P5
P5
P4
P4
P3
P3
P1
P1
D1
D1
V1
V1
R1
R1
P2
P2
COMMP
IN
COMMP
IN
POWER & COMM
OUT
POWER & COMM
OUT
Connect
T
o
Next
V
A
V/Zone Controller
On Branch Circuit
Connect
T
o
Next
V
A
V/Zone Controller
On Branch Circuit
SHLD
T
R
T
ypical T
erminal Blocks.
All
W
iring T
o
Be T T
o
T
, SHLD (G)
T
o
SHLD (G) & R T
o
R
T
G
R
485 LOOP
FILENAME
DESCRIPTION:
P
AGE
BY
:
Wiring & Connection Diagrams
JOB NAME
2 of 5
T
ypical Single Loop Networked System
W
ith MiniLink Polling Device & Modular V
A
V/Zone Controllers
Line V
oltage
VCM-X E-BUS
Unit Controller
24 V
A
C
(8 V
A
)
WARNING
OBSERVE
POLARITY
1
0
OE282
PO
WE
R
/
CO
O
MM
REC
www.orioncontrols.com
OE744-31-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
1
0
OE282
PO
WE
R
/
CO
O
MM
REC
www.orioncontrols.com
OE744-31-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
1
0
OE282
PO
WE
R
/
CO
O
MM
REC
www.orioncontrols.com
OE744-31-VAVZ
P.I. VAV/ZONE
CONTROLLER ACTUATOR
PACKAGE
O-VCMX-Network-SingleLoop1A.CDR
VCM-X E-BUS Networked System - Single Loop
Note:
For System
Manager
TS II Wiring,
See Figure 3.
S. Olson
DA
TE:
System Manager TS II
Modular Service
T
ool SD
05/12/15
Modular System
Manager SD
Figure 6: Networked Single Loop System With MiniLink PD And Modular VAV/Zone Controllers Wiring