Micros 9700 configuration – OpenEye SW-RWTCP User Manual
Page 20
![background image](https://www.manualsdir.com/files/800180/content/doc020.png)
20
MICROS 9700 CONFIGURATION
Micros 9700 Interface File
1. Open Interfaces in the EMC > Configurator.
2. Add a new record. The System Name MUST be EMON INTFC.
Note
The space between the two words of the system name is important.
3. PC Number: Select the Primary PC.
4. Service Type: 2-Security.
5. Timeout: 0.
6. Ping Frequency: 0.
7. Type: 1 – TCP.
8. TCP Host Name: Enter the IP Address of the OpenEye DVR.
9. TCP Port: Enter a TCP Port.
Note
OpenEye recommends port 5010.
Note
This port will be used in the configuration of the RediWatch software on the DVR.
10. Options: Enable Option - ”ON=9 Digit Terminal Ids, OFF=2 Digit Terminal Ids”
Enable Option - “Enable Interface Log “
This manual is related to the following products: