Operation Section
32
6.6 Compressor Overload Relay
• An external compressor overload relay is used
to protect the compressor motor. This relay is
mounted within the connector housing that
attaches to the top of the compressor. The
relay interrupts the flow of current when there
is an overload condition and, high temperature
builds up in the compressor.
6.7 Power Cord with LCDI
• This unit is equipped with a UL recognized LCDI cord and NEMA plug configuration (5-15). The
appropriate outlet must be used for this plug type. LCDI is used for monitoring leakage current.
Once leakage current is detected, LCDI de-energizes the unit.
Operating Temperature
Non-Operating Limit at 176 °F
(100 °C) (A)
Marking
OFF (Open Contacts)
ON (Closed Contacts)
302 °F (150 °C)
156 °F (69 °C)
19.0
MRA4720-12027
I001691
Bimetal
Terminal
Points
I002239
Test Button
Reset
Button