beautypg.com

Chapter 6: diagnostics and troubleshooting, 1 diagnostic mode – Microcom LDSII User Manual

Page 93

background image

LDSII Programming Guide - 880015-0123

77

Chapter 6: Diagnostics and Troubleshooting



The purpose of this chapter is to provide some information about the diagnostic reporting of
the printer that can be used to help identify, diagnose and troubleshoot problems.

6.1

Diagnostic Mode

Diagnostic Mode temporarily powers the printer using factory default parameters while
printing out the printer’s current configuration on what is called the Status Label. This
information can be used to help diagnose and troubleshoot printer configuration issues.
The default baud rate is set to 9600 and will be used when entering the diagnostic mode.
The printer will continue using the factory default parameters until printer power has been
cycled. The printer will then return to the previous configuration that was in use before
entering the diagnostic mode.


6.1.1

Entering Diagnostic Mode

To enter the diagnostic mode, press and hold the print button in while turning on the printer.
Release the button after the status light indicator starts to blink and the printer will power up
into diagnostic mode. The printer prints configuration and statistical information followed by
the ^D960)1 print head test pattern once it is powered up in the diagnostics mode.


6.1.2

Status Label

The printer will print the Status label after the printer has performed powered up and enters
the diagnostic mode. The status label prints out the reports that are generated by the
“^D323)”, “^D326)”, “^D325)”, and “^D324)” commands.














Figure 22

^D323) - List Enablements Example





Enablements (D323 or Y)

User Interface

Software flow control:

(D770) enabled

Hardware flow control:

(D771) disabled

Operational
Auto power-up script:

(D720) disabled

Auto enquiry after print:

(D721) disabled

Auto media sizing:

(D722) disabled

Auto top-of-form alignment:

(D723) disabled

Auto alignment after error:

(D724) disabled

Auto acknowledge after cmd:

(D726) disabled

Auto respond after error:

(D727) disabled

Cutter:

(D740) disabled

Printed Media Handler PMH:

(D741) disabled

This manual is related to the following products: