Printer Commands
48-466 Operators Manual
41
5.3.4 REAL-TIME CLOCK
^A
^D
Command
30
Change Clock: Use the sequence below to set the time and date of the optional real-
time socket:
^D305
HH:MM:SS5
DD/MM/YY/W5
HH = hours (24 hour format)MM = month
MM = minutes
DD = day of month
SS = seconds
YY = last 2 digits of
year
W = day of the week
1 = SUN
2 = MON
3 = TUE
4 = WED
5 = THR
6 = FRI
7 = SAT
The optional clock produces a string of text that is accessed through use of a TSN
of 0 (See Table 10 for definitions of field parameters).
The text string is shown below...
HH:MM:SS MM/DD/YY XXX DD/MM/YY XXX
...where xxx is the day of the week.
These values should be inserted into the Field parameters for proper clock text access:
Clock Field Parameters
TSN
TSP
CC
TEXT
0
1
8
HH:MM:SS
0
10
8
MM/DD/YY
0
19
3
Day of Week
0
23
8
DD/MM/YY
0
32
3
Day of Week
Table 10