Microcom 428T User Manual
Page 47

Chapter 3
Getting Started
428T Operator’s Manual - 880037-0141
3-31
-i - vertically invert the image before printing
-f
configure the driver.
Syntax: -fc:\temp\app1\app1.set
-p
the configuration.
Syntax: -p08
-d
the driver creates to work. Each driver should have a unique working directory. Please not
that a space must follow the –d switch and the path must be surrounded by quotes with an
extra “\” character.
Syntax: -d "c:\\temp\\app1"
-i - vertically invert the image before printing – The image will be inverted before the driver
converts the image.
Here is an example of the Syntax used to print labels:
C:\Program Files\MICOptions> micprint c:\temp\app1\image.bmp 0 –p08 –d "c:\\temp\\app1"
-f c:\temp\app1\app1.set
This example prints image.bmp on COMM 8 using the app1.set Micoptions configuration.
Please note that the supporting files are located at c:\temp\app.
By default, supporting files are located at the following locations:
WINDOWS XP
C:\Documents and Settings\All Users\Documents\MICPrinter
WINDOWS 7 32bit
C:\Users\Public\Documents\Micprinter
This is the location where the .set files should be copied so that the IMPORT may be
selected above to configure the printer.
It is also important to check the status of the application to make sure that the job printed
without issue.
You may use the Exit Code, %errorlevel%, to retrieve the return code from the Micprint
application.
Micprint status returns:
0 - success
-1 - unable to open image file
-2 - unknown image file type
-3 - unable to allocate memory
-4, -9, -10, -12, -13. -31 - unknown error
-5 - unsupported image resolution