beautypg.com

12 postnet (zip+4), tci 36 – Microcom 428T User Manual

Page 158

background image

Bar Codes

Chapter 8

8-6

428T Operator’s Manual - 880037-0141

Valid values for parameters
Type of GS1 Databar barcode:

0 = Omni-directional
1 = Truncated
2 = Stacked
3 = Stacked Omni-directional
4 = Limited
5 = Expanded

Multiplier:

1 to 100. This specifies how big to make the symbol. Multiplies both X & Y.

Segments per ROW:

2 to 22. EVEN number ONLY!

X Undercut:

0 to (MULTIPLIER-1)

Y Undercut:

0 to (MULTIPLIER-1)

Separator Height:

MULTIPLIER < = Separator Height < = 2 * MULTIPLIER.
Specifies the vertical separation between the linear data and the 2D data.

Data:

Always 13 digits for the linear data unless using GS1 Databar Expanded which can
be up to 74 numeric or 41 alphabetic characters.
The “pipe” character (|) is used to separate the linear data from the 2D data.

^D114

Here comes GS1 Databar data

0

Use -14 directional symbol

5

Multiply size by 5

22

Use 22 segments/row

0

X undercut = 0

0

Y undercut = 0

5

Set vertical separator = 5

0012345612345

13 digits of data

^D57

START of Label FORMAT

2,575,609,,25,35,0,1,285

TCI=35 (GS1 Databar barcode)

1,190,300,1,46
2,190,200,11,1,5
^D56

END of Label FORMAT

^D2

START of Text String

x

any character will do… this is just a placeholder

^D3

PRINT command

Figure 8-7 GS1 Databar Sample Label FORMAT


8.1.12 Postnet (ZIP+4), TCI 36

Postnet is a numeric-only symbology that is commonly used in postal application to sort
mail. The five-digit zip or five-digit zip plus four-digit extension may be used to generate this
Postnet (TCI 36) bar code. Example: 12345 or 12345-1234.