Technical Specifications TCR510

RECEIVER INPUT:

AM INPUT ( SMB-Connector ):

Insulated by transformer
Impedance:

50

, 600

Ω,

5 k

selectable by

jumper

Input signal:

abt.600 mVpp to 8 V (Mark)

other ranges on request

DC-Level Shift Input ( VG-Connector ):

Insulated by opto-coupler device
Internal series resistor: 330

Max. input current:

25 mA

Diode forward voltage:1.0 V...1.3 V

DECODING:

Decoding of the following codes possible :

IRIG-A133/A132/A003/A002

IRIG-B123/B122/B003/B002

AFNOR NFS 87-500

ACCURACY OF TIME BASE : +/- 10us compared to IRIG reference marker

REQUIRED ACCURACY OF

TIME CODE SOURCE :

+/- 100ppm

HOLDOVER MODE:

Automatic switching to crystal time base,

accuracy : see. accuracy of Oscillator

BACKUP BATTERY :

Onboard realtime clock keeps time and date

in case of power supply failure. System

parameters are stored in battery buffered ram

Lifetime of Lithium battery at least 10 years

RELIABILITY OF

OPERATION:

Microprocessor supervisory circuit generates

reset in case of brown-out, software watchdog

generates reset in case of improper program

execution

INITIALIZATION:

Initial time and date can be set by standard

Meinberg telegram via serial port COM0

PULSE OUTPUTS:

Pulse per second PPS, TTL-Level pulse, active

high, 200 ms pulse width

Pulse per minute PPM, TTL-Level pulse, active

high, 200 ms pulse width

FREQUENCY OUTPUTS:

10 MHz TTL-Level

1 MHz TTL-Level

100 kHz TTL-Level

96