Meinberg TCR LANTIME User Manual

Page 20

background image

BCD time of year, SBS time of day

A002:

1000 pps, DC Level Shift pulse width coded, no carrier

BCD time of year

B123:

100pps, amplitude modulated sine wave signal, 1 kHz carrier
frequency

BCD time of year, SBS time of day

B122:

100 pps, amplitude modulated sine wave signal, 1 kHz carrier
frequency

BCD time of year

B003:

100 pps,DC Level Shift pulse width coded, no carrier

BCD time of year, SBS time of day

B002:

100 pps, DC Level Shift pulse width coded, no carrier

BCD time of year

AFNOR NFS 87-500: 100 pps, amplitude modulated sine wave signal, 1 kHz carrier

frequency
BCD time of year, complete date, SBS time of day

Input Signals

Modulated IRIG or AFNOR-Codes are applied via the on board SMB connector.

The lead should be shielded. Unmodulated codes are applied at SUB-D connector on
rear panel. Voltages applied to this input shall not exceed 12 V. The IRIG-Code to be
used must be set at the DIP Switch.

Input for unmodulated codes

Unmodulated IRIG-Codes, often referred to as pulse with coded or DC-Level Shift

Codes ( DCLS ), are fed into the board via SUB-D connector on rear panel. Insulation
of this input is done by a opto coupler device. The input circuitry is shown below.

20