BCD time of year, SBS time of day
A002:
1000 pps, DC Level Shift pulse width coded, no carrier
BCD time of year
B123:
100pps, amplitude modulated sine wave signal, 1 kHz carrier
frequency
BCD time of year, SBS time of day
B122:
100 pps, amplitude modulated sine wave signal, 1 kHz carrier
frequency
BCD time of year
B003:
100 pps,DC Level Shift pulse width coded, no carrier
BCD time of year, SBS time of day
B002:
100 pps, DC Level Shift pulse width coded, no carrier
BCD time of year
AFNOR NFS 87-500: 100 pps, amplitude modulated sine wave signal, 1 kHz carrier
frequency
BCD time of year, complete date, SBS time of day
Input Signals
Modulated IRIG or AFNOR-Codes are applied via the on board SMB connector.
The lead should be shielded. Unmodulated codes are applied at SUB-D connector on
rear panel. Voltages applied to this input shall not exceed 12 V. The IRIG-Code to be
used must be set at the DIP Switch.
Input for unmodulated codes
Unmodulated IRIG-Codes, often referred to as pulse with coded or DC-Level Shift
Codes ( DCLS ), are fed into the board via SUB-D connector on rear panel. Insulation
of this input is done by a opto coupler device. The input circuitry is shown below.
20