Menu Reference Clock State
Pressing MENU in the main menu lets the user enter to the status menu of the
reference clocks. The name of the reference clock, the actual state and the last four
offsets to the NTP time are displayed (the left one is the newest).
TCR: 0000 clk_okay
filtoffset= -8.42 -4.23 -10.25
The state of the refclock will be displayed like "0000". The first two numbers reflects
the actually state and the second two numbers the last state of the refclock. The
following states are possible:
00: clock okay
01: clock no reply
02: clock bad format
03: clock fault
04: clock bad signal
05: clock bad date
06: clock bad time
Menu SETUP
From this menu, several topics can be selected which let the user edit parameters or
force special modes of operation. A specific topic can be selected using the NEXT
key. Depending on the current topic, pressing the CLR/ACK key either enters edit
mode with the selected set of parameters or switches to the selected mode of
operation (after the user has acknowledged his decision). Once edit mode has been
entered, the NEXT key lets the cursor move to the digit or letter to be edited whereas
the INC key increments the digit or letter under the cursor. If changes have been
made, the CLR/ACK key must be pressed. If all changes have been made in one setup
submenu you have to press the MENU key. After that you will be asked to save the
settings. Press INC to change and save the last changes. Otherwise all changes are
discarded when the user presses the MENU key in order to return to the SETUP
display.
SETUP: LAN PARAMETERS
28