SETUP LAN PARAMETERS

In this submenu the network parameters are configured. These parameters have to

be adapted to the existing network when the LANTIME is installed the first time. The
following parameters can be set: TCP/IP ADDRESS, NETMASK, DEFAULT
GATEWAY, IPv6 ADDRESS HOSTNAME, DOMAINNAME, NAMESERVER,
SYSLOG SERVER, SNMP MANAGER, REMOTE CONNECT,
RESET
FACTORY SETTINGS und NET LINK MODE
. All settings are applied to the
first Ethernet interface only. All further Ethernet interfaces have to be configured via
HTTP or CLI interface. With the submenu REMOTE CONNECT you can enable or
disable all network connections via TELNET, FTP or HTTP. When the network
parameters have been changed the configuration file is updated and the NTPD is
restarted.

TCP/IP ADDRESS
000.000.000.000

With the submenu RESET FACTORY SETTINGS the following parameters will
be set to the default values:

Reset factory settings
INC -> YES MENU -> NO

All configuration parameters of the timeserver are saved on the Flash Disk in the file /
mnt/flash/global_configuration. It is recommended not to modify this file manually
but to use the configuration interface (HTTP, CLI or SNMP). If this file does not
exist, an empty file is generated. The default configuration file is part of the
attachment.

The parameters for speed and mode of the net card can be changed with the menu
item NET LINK MODE. There are 5 modes available: Autosensing, 10 MBit/Half-
Duplex, 100 MBit/Half-Duplex, 10 MBit/Full-Duplex, 100 MBit/Full-Duplex.
Default setting is Autosensing.

SETUP TCR PARAMETERS

In this menu the parameters of the IRIG-receiver can be set. The submenu „Offset

from UTC“ lets the user set the offset from local time to UTC time. The IRIG-signal
provided no information of the offset from UTC and the receiver has to generate this
information for the NTP daemon.

SETUP: TCR PARAMETERS

Offset from UTC: +02:00

With the NEXT button the menu for the used IRIG-Code will be displayed.

SETUP: TCR PARAMETERS

IRIG Code: B122/123

29