3.

Configure a channel; steps 3(a) through (f).

DataSocket Import Setup

3(a) Select the channel that is to be configured. Note that a green socket indicates the

channel for which selected options will be applied. In the previous figure, channel

0 is selected.

3(b) For the connection Type, select OPC.

3(c) Click on the <Select Item> button.

DASYLab will search the computer registries and list every OPC server program

that resides on your computer.

3(d) Locate and expand the OPC Server Software identifier (see following figure). In

the figure we selected KEPware.KEPServerEx for the Kepware OPC Server

Software. In addition, we expanded Channel 1 to show PointScan104 and its

associated tags (Temp1 and Temp2); as well as PointScan204 (not shown in its
entirety) to show its associated channel tags (Temp3 and Temp4). You would

need to scroll down to see Temp3 and Temp4.

Expanding the Server Item

3(e) From the expanded list, select the channel tag that applies to the channel

currently being configured.
In our example tags will be assigned to channels as follows:

PointScan104 / Temp1: Channel 0

PointScan104 / Temp2: Channel 1

PointScan204 / Temp3: Channel 2
PointScan204 / Temp4: Channel 3

32

878395

PointScan Road Map