Measurement Computing PointScan Road Map rev.2.0 User Manual
Page 35

Connect DASYLab to the OPC Server
Before connecting DASYLab to the OPC Server, use KepServer’s Quick
Client feature to verify that the OPC server is receiving valid readings from
the PointScan device. A discussion of Quick Client begins on page 27.
Complete the following steps to connect DASYLab to the server.
1. From a DASYLab worksheet, access the DataSocket Import Setup screen by
navigating as follows from the toolbar (see the following left-hand figure):
⇒ Modules [pull-down menu]
⇒ Network
⇒ DataSocket Import (left-click to bring up a DataSocket Import Icon)
Double-click on the DataSocket Import Icon (not shown) to open the
DataSocket Import Setup dialog box (see the following right-hand figure).
Selecting DataSocket Import
DataSocket Import Setup
2. Click on the triangular add button [item 2 in the above figure] to add the desired number
of channels. Each click of the button will sequentially place a socket image beneath a
channel. In the preceding figure socket images can be seen for channels 0, 1, 2, and 3.
Note: If your system has more than 16 channels, you will need to put an additional
DataSocket Import module on your worksheet.
PointScan Road Map
878395
31