Error Number and Message Text

Description

00

OK

No error has occurred.

01

TIME OUT - NOT ADDRESSED TO LISTEN

ENTER as a Peripheral did not receive data within the

TIME OUT period.

02

AUTOINITIALIZE MODE NOT ALLOWED

This error message is obsolete in Driver488 Rev.3.0.

03

SYSTEM ERROR - BUFFER MODE NOT SUPPORTED

Internal system error. Report to factory.

04

TIME OUT ERROR ON DATA READ

Expected bus data was not received within the TIME OUT

period.

05

SYSTEM ERROR - INVALID INTERNAL MODE

Internal system error. Report to factory.

06

INVALID CHANNEL FOR DMA

This error message is obsolete in Driver488 Rev.4.0.

07

TIME OUT ON DMA TRANSFER

This error message is obsolete in Driver488 Rev.4.0.

08

TIME OUT - NOT ADDRESSED TO TALK

OUTPUT as a Peripheral was not possible within the TIME

OUT period.

09

TIME OUT OR BUS ERROR ON WRITE

Error occurred transferring a data byte to a bus service.

10

SEQUENCE - NO DATA AVAILABLE

The user’s program attempted to read from Driver488 when

no response or data was available.

11

SEQUENCE - DATA HAS NOT BEEN READ

The user’s program attempted to write data or commands to

Driver488 without reading back the response to a
previous command.

12

SYSTEM ERROR - ON PEN INTS ALREADY ON

Internal system error. Report to factory.

13

SYSTEM ERROR - INVALID ON PEN INIT

Internal system error. Report to factory.

14

SYSTEM ERROR - LIKELY MEMORY CORRUPTION

Internal system error. Report to factory.

15

SYSTEM ERROR - ON PEN INTS ALREADY OFF

Internal system error. Report to factory.

16

BOARD DOES NOT RESPOND AT SPECIFIED

ADDRESS

Driver488 is unable to communicate with the IEEE

interface board. Check the board address
configuration, and the software installation.

17

TIME OUT ON COMMAND (MTA)

MyTalkAddress could not be sent within the TIME OUT

period.

18

TIME OUT ON COMMAND (MLA)

MyListenAddress could not be sent within the TIME OUT

period.

19

TIME OUT ON COMMAND (LAG)

Listen address(es) could not be sent within the TIME OUT

period.

20

TIME OUT ON COMMAND (TAG)

Talk address could not be sent within the TIME OUT

period.

21

TIME OUT ON COMMAND (UNL)

UnListen could not be sent within the TIME OUT period.

22

TIME OUT ON COMMAND (UNT)

UnTalk could not be sent within the TIME OUT period.

23

ONLY AVAILABLE TO SYSTEM CONTROLLER

Driver488 could not execute a command because it was not

the System Controller.

24

RESPONSE MUST BE 0 THROUGH 15

The RESPONSE parameter of the PPOLL CONFIG

command must be within the range of 0 to 15.

25

NOT A PERIPHERAL

The REQUEST command is only valid when Driver488 is
in the Peripheral (*CA) mode.

26

SYSTEM ERROR - TIMER INTS ALREADY ON

Internal system error. Report to factory.

27

SYSTEM ERROR - INVALID TIMER INIT

Internal system error. Report to factory.

28

SYSTEM ERROR - TIMER INTS ALREADY OFF

Internal system error. Report to factory.

29

ADDRESS REQUIRED

PASS CONTROL requires an address.

30

TIME OUT VALUE MUST BE FROM 0 TO 65535

The TIME OUT period must be within the specified range.