Appendices, Appendix a - api error codes, A – api error codes …… a-1 – Measurement Computing Personal488 rev.3.0 User Manual
Page 133: Appendix a, Api error codes

Personal488 for Windows 95/98/Me/NT/2000
04-10-01
API Error Codes A-1
Appendix
A
API Error Codes
Error Number and Message Text
Description
00
OK
No error has occurred.
01
TIME OUT - NOT ADDRESSED TO LISTEN
ENTER as a Peripheral did not receive data within the
TIME OUT period.
02
AUTOINITIALIZE MODE NOT ALLOWED
This error message is obsolete in Driver488 Rev.3.0.
03
SYSTEM ERROR - BUFFER MODE NOT SUPPORTED
Internal system error. Report to factory.
04
TIME OUT ERROR ON DATA READ
Expected bus data was not received within the TIME OUT
period.
05
SYSTEM ERROR - INVALID INTERNAL MODE
Internal system error. Report to factory.
06
INVALID CHANNEL FOR DMA
This error message is obsolete in Driver488 Rev.4.0.
07
TIME OUT ON DMA TRANSFER
This error message is obsolete in Driver488 Rev.4.0.
08
TIME OUT - NOT ADDRESSED TO TALK
OUTPUT as a Peripheral was not possible within the TIME
OUT period.
09
TIME OUT OR BUS ERROR ON WRITE
Error occurred transferring a data byte to a bus service.
10
SEQUENCE - NO DATA AVAILABLE
The user’s program attempted to read from Driver488 when
no response or data was available.
11
SEQUENCE - DATA HAS NOT BEEN READ
The user’s program attempted to write data or commands to
Driver488 without reading back the response to a
previous command.
12
SYSTEM ERROR - ON PEN INTS ALREADY ON
Internal system error. Report to factory.
13
SYSTEM ERROR - INVALID ON PEN INIT
Internal system error. Report to factory.
14
SYSTEM ERROR - LIKELY MEMORY CORRUPTION
Internal system error. Report to factory.
15
SYSTEM ERROR - ON PEN INTS ALREADY OFF
Internal system error. Report to factory.
16
BOARD DOES NOT RESPOND AT SPECIFIED
ADDRESS
Driver488 is unable to communicate with the IEEE
interface board. Check the board address
configuration, and the software installation.
17
TIME OUT ON COMMAND (MTA)
MyTalkAddress could not be sent within the TIME OUT
period.
18
TIME OUT ON COMMAND (MLA)
MyListenAddress could not be sent within the TIME OUT
period.
19
TIME OUT ON COMMAND (LAG)
Listen address(es) could not be sent within the TIME OUT
period.
20
TIME OUT ON COMMAND (TAG)
Talk address could not be sent within the TIME OUT
period.
21
TIME OUT ON COMMAND (UNL)
UnListen could not be sent within the TIME OUT period.
22
TIME OUT ON COMMAND (UNT)
UnTalk could not be sent within the TIME OUT period.
23
ONLY AVAILABLE TO SYSTEM CONTROLLER
Driver488 could not execute a command because it was not
the System Controller.
24
RESPONSE MUST BE 0 THROUGH 15
The RESPONSE parameter of the PPOLL CONFIG
command must be within the range of 0 to 15.
25
NOT A PERIPHERAL
The REQUEST command is only valid when Driver488 is
in the Peripheral (*CA) mode.
26
SYSTEM ERROR - TIMER INTS ALREADY ON
Internal system error. Report to factory.
27
SYSTEM ERROR - INVALID TIMER INIT
Internal system error. Report to factory.
28
SYSTEM ERROR - TIMER INTS ALREADY OFF
Internal system error. Report to factory.
29
ADDRESS REQUIRED
PASS CONTROL requires an address.
30
TIME OUT VALUE MUST BE FROM 0 TO 65535
The TIME OUT period must be within the specified range.