INSTRUCTION/INSTALLATION SHEET
1x11 Telecom Modules

IS-0011 REV. G

©Copyright 2008 by On-Q/Legrand All Rights

Reserved

.

1. Introduction

The On-Q/Legrand 1x11
Telecom Modules provide a
structured method for
distributing telephone service
and wide area network data
service throughout the house.
This instruction sheet covers the
1x11 Standard Telecom Module
(P/N 363484-01) and the 1x11
KSU/PBX Module (P/N 363485-
01) shown in Figure 1. The
modules can be directly
mounted in any On-Q style
enclosure.


2. Description

Both 1x11 Telecom Modules come with one 110-style punch down connector for connecting to the 4-line
incoming telecom service and eleven 110-style punch down connectors for connecting to the telecom outlets in
each room. Both modules also come with a 20-pin posted connector and spade terminal for an optional surge
protector (P/N 363487-01), an RJ-45 jack for test or local handset attachment, an RJ-45 jack for connection to an
RJ-31x security interface and a 4-position switch to allow separation of the incoming lines from the outlets for
testing purposes. Both modules also come with an identical WAN interface area with incoming and outgoing RJ-
45 jacks and 110-style punch down connectors. The 1x11 KSU/PBX Module also comes with two 50-pin style
telco connectors typically connected to KSU/PBXes or punch down blocks.

NOTE: This product is listed as UL 1863 – Communications Circuit Accessories and complies with
General Approval NS/G/1235/W/100025.


3. Installation

A. Mounting in enclosure (see Figure 2)

1) Align tabs on module with slots in enclosure.
2) Insert tabs by angling module away from the back of the enclosure

and sliding forward.

3) Rotate the module and insert fasteners on module into corresponding

holes in the enclosure. (Plunger must be in the pulled out position for
fastener to engage hole.)

4) Push plunger in to lock module in place. Pull on module to assure

module is locked properly in place.


B. Incoming Service Cable Installation (see Figure 3)

1) Route incoming service Cat 5e cable to “Line In” 110-style punch down

block, allowing slack for bundling, and cut cable about 2” past
connector.

Figure 2

Figure 1

on

·

Q

on

·

Q