Legrand AC1023 User Manual
Is-0504 rev. b
INSTRUCTION / INSTALLATION SHEET
Intercom / Unity Relay Module (P/N
AC1023)
IS-0504 Rev. B
301Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
©Copyright 2011 by Legrand All Rights Reserved.
Page 1 of 2
1. Introduction
The Legrand AC1023 Intercom/Unity Relay Module
(see Figure 1) provides the relay interface between
the SCI Intercom Module (IC5001) or Unity Integration
Module (HA6001) and a third party electronic door
strike. This relay module supports a remote door
release capability as part of an SCI Intercom or Unity
system. It supports a 12 VDC door strike and is
powered by an appropriate third party AC to DC power
supply.
2. Description
• Provides one 2.5mm DIN jack (or 2-pin cage connector labeled “POWER”) for connection to a third party 12 VDC
AC to DC power adapter.
• Provides one 2-pin cage connector (labeled “CTRL”) for connection to the SCI or Unity Integration Module.
• Provides one 2-pin cage connector (labeled “OUT”) for connection (up to 2A) to the electronic door strike.
• Provides one 4-pin cage connector (labeled “DRY CONTACT”) that supports a Normally Closed (plus Common)
and Normally Open (plus Common) connections for use when a dry contact is used to initiate the door strike
(rather than the SCI or Unity system).
3. Installation
Installation of the Legrand AC1023 and related components is best accomplished at multiple times during new
construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and painted
(see Figure 2).
IMPORTANT: Read the manuals that are included with all associated Unity products before installation of
any single component. If you are unsure of any of the following installation procedures contact Legrand
Technical Support @ 1-800-321-2343 option 1 or contact a Legrand installer.
A. “Rough-in”
steps:
1. AC1023:
Run a 16/2 cable from the door release location to the enclosure housing the
AC1023.
2. AC1023 (optional):
Run a 16/2 cable from the optional Normally Closed or Normally Open contact
location to the enclosure housing the AC1023.
B. “Trim-out”
steps:
NOTE: Make sure that the 12VDC Power Supply is not connected to the AC1023 Module.
1. Install the AC1023 in the enclosure by first attaching it to a single bay opening in an existing
bracket using the four corner plungers.
Figure 1