Legrand AU0100-WHLA-V1 User Manual
Page 3
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 3 of 3
INSTRUCTION/INSTALLATION SHEET
Speaker Level / Impedance Matching
Volume Control
IS-1507094 REV. O
©Copyright 2009 by On-Q/Legrand All Rights Reserved.
6) After load capacity is determined, refer
to Figure 4 to determine the proper
multiplier setting for all the volume
controls.
NOTE: Multiplier setting #1 refers to
jumper position X1, multiplier setting #2
refers to jumper position X2, multiplier
setting #3 refers to jumper position X4
and multiplier setting 4 refers to jumper
position X8 (see Figure 6).
7) Position the jumper plug on the two
pins relating to the appropriate
multiplier setting (X1, X2, X4, or X8)
see Figure 6).
NOTE: Although there are jumpers for
each speaker’s output, in most cases
they will be set exactly the same.
NOTE: Rotating the volume control fully
counter clockwise will yield no power
going to the speakers (off).
C. To change color:
1) Pull off knob.
2) Unscrew
coverplate.
3) Unsnap inner cover.
4) Snap on new inner cover.
5) Screw on new coverplate.
6) Push on new knob.
Formula for calculating impedance of parallel speakers:
1/x ohms + 1/x ohms = 1/y impedance
1/8 ohms + 1/8 ohms = 2/8 ohms or 1/ 4 ohms
(2 - 8 ohm speakers in parallel exhibit 4 ohms of impedance)
NOTE: Speakers wired in series exhibit purely additive
impedance (8+8 + 16).
Figure 5