Legrand TITAN Series v.4 User Manual
Titan, Installation instructions
TITAN
™
INSTALLATION INSTRUCTIONS
INCANDESCENT DIMMERS, MAGNETIC LOW VOLTAGE DIMMERS,
FAN SPEED CONTROLS, DEHUMMER FAN SPEED CONTROLS,
FLUORESCENT DIMMERS
P/N 340840 Rev. B
INCANDESCENT DIMMERS “CD” SERIES: These dimmers are for use with
Incandescent and Halogen lamps.
CAUTION: To reduce the risk of overheating and possible damage to other
equipment, do not install to control a receptacle, a fluorescent light, a motor-
operated appliance, or a transformer supplied appliance.
• Do not use this dimmer with incandescent lamps whose power
requirements exceeds maximum power (stated in Watts) of this control.
• Do not connect this dimmer to power source other than 120VAC, 60 Hz only.
• Use copper wire only.
• A 50W minimum load is required.
MAGNETIC LOW VOLTAGE DIMMERS “CDLV” SERIES: These dimmers are for
use with Magnetic Low Voltage Incandescent and Halogen lamps.
CAUTION: To reduce the risk of overheating and possible damage to other
equipment, do not install to control a receptacle, a fluorescent light, or a
motor-operated appliance. Connect only in a 120VAC, 60Hz circuit to control
the primary winding of a transformer supplied incandescent and halogen
lamp. The maximum VA rating of this dimmer applies to the transformer
input, not the load on the transformer secondary.
• Do not use to control a solid state electronic low voltage transformer.
• Do not use with inoperative or missing lamps. Use of this dimmer with
inoperative or missing lamps can create an over current condition which
may damage the transformer. Use transformers that incorporate thermal
protection or a fuse at the primary windings.
• Use copper wire only.
• A 50VA minimum load is required.
FAN SPEED CONTROLS “CDSC” SERIES: These controls are for use with Fan
or Blower units. Use only with Fan or Blower units marked “Suitable for Use
with Solid State Fan Speed Controls”. Set multi-speed fans to their highest
setting before installing this control.
• Do not use this control with Fan or Blower units that exceed the maximum
power (stated in Amps) of this control.
• Do not connect this control to power source other than 120VAC, 60 Hz only.
• Use copper wire only.
• A 0.25 Amp minimum load is required.
DEHUMMER FAN SPEED CONTROLS “CDDH” SERIES: These controls are for
use with a single ceiling paddle fan only.
• Do not use this control with a ceiling paddle fan that exceeds the maximum
power (stated in Amps) of this control.
• Do not connect this control to power source other than 120VAC, 60 Hz only.
• Use copper wire only.
FLUORESCENT DIMMERS “CDFB” SERIES: These dimmers control dimmable
ballasts:
• Use copper wire only.
• A 0.25 Amp minimum load is required.
• These dimmers are compatible with the following ballasts:
PACKAGE CONTENTS
One of the following Dimmers:
Narrow Dimmers
Wide Dimmers
Cat no.:
Cat no.:
Cat no.:
Cat no.:
CD700
CD703P
CD1600
CD1603P
CD1100
CD1103P
CD2000
CD2003P
CDLV700
CDLV703P
CDLV1600
CDLV1603P
CDLV1100
CDLV1103P
CDFB10
CDFB103P
CDFB5
CDFB53P
CDFB16
CDFB163P
CDFB8
CDFB83P
CDFB7-277
CDFB73P-277
CDSC6
CDFB10-277
CDFB103P-277
CDDH16
CDSC12
Wire Nuts
Coupler
Small Coupler
WALL PLATE LABELING SYSTEM
These dimmer wall plates contain a label holding slot. A
0.33" x 1.5" label can be placed in this label holding slot.
These labels can be printed from an Avery® standard
template: Divider tab inserts 8-Tabs or equivalent.
Install the label with the following procedure:
1. Disconnect power to the circuit by removing fuse or
turning circuit breakers OFF.
2. Remove the wall plate by
placing a small flat head
screwdriver into one of
the four slots located at
the top and bottom of the
wall plate. Gently twist a
half turn until the plate
pops off.
3. Slide the label in from the
back side of the wall
plate (as shown at right).
P.O. Box 4822, Syracuse, NY 13221-4822
(800-223-4185)
www.passandseymour.com
P/N 340840 Rev. B
MULTI GANG INSTALLATION INSTRUCTIONS
FINS ARE REMOVED
NOTE: A
3
gang Installation
of Narrow Dimmers is shown and
described below. Any Combination of
Wide and Narrow Dimmers will gang
the same way.
1. Select the correct box size from
Table 3.
Table 3 – Wall-box Gang
Requirements – FINS are REMOVED
2. Remove the End Cap and break the fins between adjacent dimmers (2 screws
for each End Cap). Keep these screws as they will be needed at step #5.
NOTE: The End Cap and the Fins that are not between dimmers do NOT
get removed.
3. Connect the dimmer as shown in the wiring diagram using the appropriate
sized wire connectors.
4. With the word “TOP” up, install dimmer in the wall box using mounting
screws provided (leave mounting screws “finger tight” at this point).
Narrow Dimmers
0
1
2
3
4
5
6
0
0
1
2
3
4
5
6
1
1
3
4
5
6
7
8
2
3
4
5
6
7
8
9
3
5
6
7
8
9
10
11
4
7
8
9
10
11
12
13
5
9
10
11
12
13
14
15
6
11
12
13
14
15
16
17
W
id
e
D
im
m
er
s
Remove this
screw to
remove End Cap
End Cap
Remove this
screw to
remove End Cap
Remove fins
between
adjacent
dimmers
using a
vise or
heavy-duty
pliers
Fins are removed between adjacent dimmers
5. Attach the Small Couplers between the Dimmers with the screws that were
removed in step 2.
6. Tighten the mounting screws, insert the label, attach the wall plate, and
restore power to the circuit.
7. Calibrate the Dimmer if necessary – Refer to Single Gang Installation
Instructions, step #7.
WARRANTIES
Lifetime Warranty. The device you have purchased is warranted under normal use
against defects in workmanship and materials for as long as you own the device. If the
device fails due to manufacturing defect during normal use, return the device for
replacement to the store where purchased or send to:
Pass & Seymour Legrand
50 Boyd Avenue
Syracuse, NY 13209
All requests for replacement must include a dated sales receipt (legible copies
acceptable).
ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO A
PERIOD OF TWO YEARS FROM THE DATE OF PURCHASE. YOUR SOLE AND EXCLUSIVE
REMEDY AGAINST PASS & SEYMOUR LEGRAND UNDER ANY WARRANTY SHALL BE THE
EQUIVALENT REPLACEMENT OF THE DEVICE. IN NO EVENT SHALL ANY WARRANTY
APPLY TO ANY DEFECT ARISING OUT OF ANY ALTERATION OF THE DEVICE, IMPROPER
WIRING, IMPROPER INSTALLATION, MISUSE, ABNORMAL USE OR NEGLIGENCE. IN NO
EVENT SHALL PASS & SEYMOUR LEGRAND BE LIABLE FOR LOST PROFITS, INDIRECT,
SPECIAL, EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do
not allow limitations on how long implied warranties last and do not allow exclusion or
limitation of incidental or consequential damages. Some of the above limitations or
exclusions may not apply to every purchaser.
Small Couplers
Compatible
P&S Cat #
CDFB5
CDFB8
CDFB53P
CDFB83P
CDFB10
CDFB16
CDFB103P
CDFB163P
CDFB7-277
CDFB10-277
CDFB73P-277
CDFB103P-277
Model
REZ-132-SC, REZ-2S32-SC, REZ-3S32-SC,
REZ-154, REZ-2S54, REZ-1Q18-M2, REZ-
2Q18-M2, REZ-1T42-M2, REZ-2T42-M3,
REZ-1TTS40/REZ-1TTS40-SC, REZ-
2TTS40/REZ-2TTS40-SC,IEZ-2S24-D, REB-
2S26-M1-LS-DIM/REB-2S26-M1-BS-DIM
2W-T426-120-1-S, 2W-T426-120-2-S, 2W-
T432-120-1-S, 2W-T432-120-2-S, 2W-
T832-120-1-S, 2W-T832-120-2-S
QTP1x32T8/UNV DIM, QTP2x32T8/UNV
DIM, QTP3x32T8/UNV, DIM, QTP4x32T8/
UNV DIM
VEZ-132-SC, VEZ-2S32-SC, VEZ-3S32-SC,
VEZ-154, VEZ-2S54, VEZ-1Q18-M2, VEZ-
2Q18-M2, VEZ-1T42-M2, VEZ-2T42-M3,
VEZ-1TTS40/VEZ-1TTS40-SC, VEZ-2TTS40/
VEZ-2TTS40-SC, IEZ-2S24-D
QTP1x32T8/UNV DIM, QTP2x32T8/UNV
DIM, QTP3x32T8/UNV, DIM, QTP4x32T8/
UNV DIM
Voltage
120VAC
60 HZ
277VAC
60 HZ
Ballast
Manufacturer
Advance
Lutron
Sylvania/Osram
Advance
Sylvania/Osram
Couplers
6. Tighten the mounting screws, insert the label, attach the wall plate, and
restore power to the circuit.
7. Calibrate the Dimmer if necessary – Refer to Single Gang Installation
Instructions, step #7.
CAUTION: To be installed by a certified electrician or other qualified person.
WARNING: To prevent severe shock or electrocution, always turn power
OFF at the service panel before installing this dimmer, working on the
circuit, or changing a lamp.
• To be installed by a certified electrician or other qualified person.