beautypg.com

Legrand TITAN Series v.4 User Manual

Titan, Installation instructions

background image

TITAN

INSTALLATION INSTRUCTIONS

INCANDESCENT DIMMERS, MAGNETIC LOW VOLTAGE DIMMERS,

FAN SPEED CONTROLS, DEHUMMER FAN SPEED CONTROLS,

FLUORESCENT DIMMERS

P/N 340840 Rev. B

INCANDESCENT DIMMERS “CD” SERIES: These dimmers are for use with

Incandescent and Halogen lamps.
CAUTION: To reduce the risk of overheating and possible damage to other

equipment, do not install to control a receptacle, a fluorescent light, a motor-

operated appliance, or a transformer supplied appliance.
• Do not use this dimmer with incandescent lamps whose power

requirements exceeds maximum power (stated in Watts) of this control.

• Do not connect this dimmer to power source other than 120VAC, 60 Hz only.

• Use copper wire only.

• A 50W minimum load is required.
MAGNETIC LOW VOLTAGE DIMMERS “CDLV” SERIES: These dimmers are for

use with Magnetic Low Voltage Incandescent and Halogen lamps.
CAUTION: To reduce the risk of overheating and possible damage to other

equipment, do not install to control a receptacle, a fluorescent light, or a

motor-operated appliance. Connect only in a 120VAC, 60Hz circuit to control

the primary winding of a transformer supplied incandescent and halogen

lamp. The maximum VA rating of this dimmer applies to the transformer

input, not the load on the transformer secondary.
• Do not use to control a solid state electronic low voltage transformer.

• Do not use with inoperative or missing lamps. Use of this dimmer with

inoperative or missing lamps can create an over current condition which

may damage the transformer. Use transformers that incorporate thermal

protection or a fuse at the primary windings.

• Use copper wire only.

• A 50VA minimum load is required.
FAN SPEED CONTROLS “CDSC” SERIES: These controls are for use with Fan

or Blower units. Use only with Fan or Blower units marked “Suitable for Use

with Solid State Fan Speed Controls”. Set multi-speed fans to their highest

setting before installing this control.
• Do not use this control with Fan or Blower units that exceed the maximum

power (stated in Amps) of this control.

• Do not connect this control to power source other than 120VAC, 60 Hz only.

• Use copper wire only.

• A 0.25 Amp minimum load is required.
DEHUMMER FAN SPEED CONTROLS “CDDH” SERIES: These controls are for

use with a single ceiling paddle fan only.
• Do not use this control with a ceiling paddle fan that exceeds the maximum

power (stated in Amps) of this control.

• Do not connect this control to power source other than 120VAC, 60 Hz only.

• Use copper wire only.
FLUORESCENT DIMMERS “CDFB” SERIES: These dimmers control dimmable

ballasts:
• Use copper wire only.

• A 0.25 Amp minimum load is required.

• These dimmers are compatible with the following ballasts:

PACKAGE CONTENTS

One of the following Dimmers:

Narrow Dimmers

Wide Dimmers

Cat no.:

Cat no.:

Cat no.:

Cat no.:

CD700

CD703P

CD1600

CD1603P

CD1100

CD1103P

CD2000

CD2003P

CDLV700

CDLV703P

CDLV1600

CDLV1603P

CDLV1100

CDLV1103P

CDFB10

CDFB103P

CDFB5

CDFB53P

CDFB16

CDFB163P

CDFB8

CDFB83P

CDFB7-277

CDFB73P-277

CDSC6

CDFB10-277

CDFB103P-277

CDDH16

CDSC12

Wire Nuts

Coupler

Small Coupler

WALL PLATE LABELING SYSTEM

These dimmer wall plates contain a label holding slot. A

0.33" x 1.5" label can be placed in this label holding slot.

These labels can be printed from an Avery® standard

template: Divider tab inserts 8-Tabs or equivalent.
Install the label with the following procedure:
1. Disconnect power to the circuit by removing fuse or

turning circuit breakers OFF.

2. Remove the wall plate by

placing a small flat head

screwdriver into one of

the four slots located at

the top and bottom of the

wall plate. Gently twist a

half turn until the plate

pops off.

3. Slide the label in from the

back side of the wall

plate (as shown at right).

P.O. Box 4822, Syracuse, NY 13221-4822
(800-223-4185)
www.passandseymour.com

P/N 340840 Rev. B

MULTI GANG INSTALLATION INSTRUCTIONS

FINS ARE REMOVED

NOTE: A

3

gang Installation

of Narrow Dimmers is shown and
described below. Any Combination of
Wide and Narrow Dimmers will gang
the same way.

1. Select the correct box size from

Table 3.

Table 3 – Wall-box Gang
Requirements – FINS are REMOVED

2. Remove the End Cap and break the fins between adjacent dimmers (2 screws

for each End Cap). Keep these screws as they will be needed at step #5.
NOTE: The End Cap and the Fins that are not between dimmers do NOT
get removed.

3. Connect the dimmer as shown in the wiring diagram using the appropriate

sized wire connectors.

4. With the word “TOP” up, install dimmer in the wall box using mounting

screws provided (leave mounting screws “finger tight” at this point).

Narrow Dimmers

0

1

2

3

4

5

6

0

0

1

2

3

4

5

6

1

1

3

4

5

6

7

8

2

3

4

5

6

7

8

9

3

5

6

7

8

9

10

11

4

7

8

9

10

11

12

13

5

9

10

11

12

13

14

15

6

11

12

13

14

15

16

17

W

id

e

D

im

m

er

s

Remove this

screw to

remove End Cap

End Cap

Remove this

screw to

remove End Cap

Remove fins

between

adjacent

dimmers

using a

vise or

heavy-duty

pliers

Fins are removed between adjacent dimmers

5. Attach the Small Couplers between the Dimmers with the screws that were

removed in step 2.

6. Tighten the mounting screws, insert the label, attach the wall plate, and

restore power to the circuit.

7. Calibrate the Dimmer if necessary – Refer to Single Gang Installation

Instructions, step #7.

WARRANTIES

Lifetime Warranty. The device you have purchased is warranted under normal use
against defects in workmanship and materials for as long as you own the device. If the
device fails due to manufacturing defect during normal use, return the device for
replacement to the store where purchased or send to:

Pass & Seymour Legrand

50 Boyd Avenue

Syracuse, NY 13209

All requests for replacement must include a dated sales receipt (legible copies
acceptable).
ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO A
PERIOD OF TWO YEARS FROM THE DATE OF PURCHASE. YOUR SOLE AND EXCLUSIVE
REMEDY AGAINST PASS & SEYMOUR LEGRAND UNDER ANY WARRANTY SHALL BE THE
EQUIVALENT REPLACEMENT OF THE DEVICE. IN NO EVENT SHALL ANY WARRANTY
APPLY TO ANY DEFECT ARISING OUT OF ANY ALTERATION OF THE DEVICE, IMPROPER
WIRING, IMPROPER INSTALLATION, MISUSE, ABNORMAL USE OR NEGLIGENCE. IN NO
EVENT SHALL PASS & SEYMOUR LEGRAND BE LIABLE FOR LOST PROFITS, INDIRECT,
SPECIAL, EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do
not allow limitations on how long implied warranties last and do not allow exclusion or
limitation of incidental or consequential damages. Some of the above limitations or
exclusions may not apply to every purchaser.

Small Couplers

Compatible

P&S Cat #

CDFB5
CDFB8

CDFB53P
CDFB83P

CDFB10
CDFB16

CDFB103P
CDFB163P

CDFB7-277

CDFB10-277

CDFB73P-277

CDFB103P-277

Model

REZ-132-SC, REZ-2S32-SC, REZ-3S32-SC,
REZ-154, REZ-2S54, REZ-1Q18-M2, REZ-
2Q18-M2, REZ-1T42-M2, REZ-2T42-M3,
REZ-1TTS40/REZ-1TTS40-SC, REZ-
2TTS40/REZ-2TTS40-SC,IEZ-2S24-D, REB-
2S26-M1-LS-DIM/REB-2S26-M1-BS-DIM

2W-T426-120-1-S, 2W-T426-120-2-S, 2W-
T432-120-1-S, 2W-T432-120-2-S, 2W-
T832-120-1-S, 2W-T832-120-2-S

QTP1x32T8/UNV DIM, QTP2x32T8/UNV
DIM, QTP3x32T8/UNV, DIM, QTP4x32T8/
UNV DIM

VEZ-132-SC, VEZ-2S32-SC, VEZ-3S32-SC,
VEZ-154, VEZ-2S54, VEZ-1Q18-M2, VEZ-
2Q18-M2, VEZ-1T42-M2, VEZ-2T42-M3,
VEZ-1TTS40/VEZ-1TTS40-SC, VEZ-2TTS40/
VEZ-2TTS40-SC, IEZ-2S24-D

QTP1x32T8/UNV DIM, QTP2x32T8/UNV
DIM, QTP3x32T8/UNV, DIM, QTP4x32T8/
UNV DIM

Voltage

120VAC

60 HZ

277VAC

60 HZ

Ballast

Manufacturer

Advance

Lutron

Sylvania/Osram

Advance

Sylvania/Osram

Couplers

6. Tighten the mounting screws, insert the label, attach the wall plate, and

restore power to the circuit.

7. Calibrate the Dimmer if necessary – Refer to Single Gang Installation

Instructions, step #7.

CAUTION: To be installed by a certified electrician or other qualified person.

WARNING: To prevent severe shock or electrocution, always turn power

OFF at the service panel before installing this dimmer, working on the

circuit, or changing a lamp.
• To be installed by a certified electrician or other qualified person.

This manual is related to the following products: