Legrand PT2095HG Series PlugTail GFCI Receptacle User Manual
Installing and testing a plugtail, Gfci receptacle, Should you install it
• To prevent severe shock or electro-
cution, always turn the power OFF
at the service panel before working
with wiring.
• Use this GFCI receptacle with
copper or copper-clad wire. Do
not use it with aluminum wire.
• Do not install this GFCI receptacle
on a circuit that powers life support
equipment because if the GFCI
trips, it will shut down the
equipment.
• For installation in wet locations,
protect the GFCI receptacle with
a weatherproof cover that will
keep both the receptacle and any
plugs dry.
• Must be installed in accordance
with national and local electrical
codes.
3. Should you install it?
Installing a GFCI receptacle can be
more complicated than installing a
conventional receptacle.
Make sure that you:
• Understand basic wiring principles
and techniques.
• Can interpret wiring diagrams.
• Have circuit wiring experience.
• Are prepared to take a few minutes
to test your work, making sure that
you have wired the GFCI receptacle
correctly.
4. Turn the power OFF
Plug an electrical device, such as a lamp
or radio, into the receptacle on which
you are working. Turn the lamp or radio
on. Then, go to the service panel. Find
the breaker or fuse that protects that
receptacle. Place the breaker in the OFF
position or completely remove the fuse.
The lamp or radio should turn OFF.
Next, plug in and turn ON the lamp or
radio at the receptacle’s other outlet to
make sure the power is OFF at both
outlets. If the power is not OFF, stop
work and call an electrician to complete
the installation.
RESET
RESET
TEST
TEST
General Information
Ratings:
15A 125V 60Hz
20A 125V 60Hz
Technical Assistance: (800) 223-4185
www.passandseymour.com
Part No. 340769 Rev. B
LIMITED ONE YEAR WARRANTY
Pass & Seymour will remedy any defect in workmanship or material in Pass & Seymour products which may
develop under proper and normal use within one year from date of purchase by a consumer:
(1) by repair or replacement, or, at Pass & Seymour’s option, (2) by return of an amount equal to consumer’s
purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour does
not include or cover cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER
ELEMENTS OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL
EXPRESSED OR IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE ARE EXCLUDED HEREBY. (Some states do not allow disclaimers or
exclusion or limitation of incidental or consequential damages, so the above disclaimer and limitation or
exclusion may not apply to you.) ANY IMPLIED WARRANTIES INCLUDING WHERE REQUIRED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE ONE
YEAR PERIOD SET FORTH ABOVE. (Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.)
To insure safety, all repairs to Pass & Seymour products must be made by Pass & Seymour, or under its specific
direction. Procedure to obtain performance of any warranty obligation is as follows: (1) Contact Pass &
Seymour, Syracuse, New York 13221, for instructions concerning return or repair; (2) return the product to Pass
& Seymour, postage paid, with your name and address and a written description of the installation or use of
the Pass & Seymour product, and the observed defects or failure to operate, or other claimed basis for
dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state
1. What is a GFCI?
A GFCI receptacle is different from
conventional receptacles. In the event
of a ground fault, a GFCI will trip and
quickly stop the flow of electricity to
prevent serious injury.
Definition of a ground fault:
Instead of following its normal safe
path, electricity passes through a
person’s body to reach the ground.
For example, a defective appliance
can cause a ground fault.
A GFCI receptacle does not protect
against circuit overloads, short circuits,
or shocks. For example, you can still be
shocked if you touch bare wires while
standing on a non-conducting surface
such as a wood floor.
Procedure:
(a) Turn the power ON at the service panel. Press the RESET button fully.
The RESET button should stay in. Plug a lamp or radio into the GFCI
(and leave it plugged in) to verify that the power is ON. If there is no
power, turn the power OFF and check the wire connections (Step 5).
Make sure that there are no loose wires or loose connections and verify
that the PT Series Connector is snapped into the PlugTail™ GFCI.
(b) Press the TEST button in order to trip the device. This should stop the
flow of electricity, making the radio or lamp shut OFF and the GFCI’s
red Trip Indicator Light come on. Note that the RESET button will
pop-out. If the power goes OFF, you have installed the GFCI
receptacle correctly. To restore power, press the RESET button.
(c) Press the TEST button (then RESET button) every month to assure
proper operation.
(d) This GFCI will trip and be unable to be reset (no output power) when
it has reached its end-of-life. To confirm that the GFCI has reached its
end-of-life, unplug the appliances connected to the GFCI and press
the Reset Button. If the GFCI continues to trip, then the GFCI has
reached its end-of-life and should be replaced. If the GFCI resets, the
appliance may be defective.
2. The GFCI’s features
FRONT VIEW
Receptacle
Outlet
TEST button:
See step 6
Trip Indicator
Light
Reset button:
See step 6
Outlet
Mounting
bracket
Installing and
Testing a PlugTail
™
GFCI Receptacle
For Use Only with Pass and Seymour
PT Series Connector.
Please read this leaflet completely
before getting started.
CAUTION
!
1. Disconnect power.
2. Attach connection to branch circuit
wiring.
Black wire to
Hot wire;
(connector)
(branch circuit wiring)
White wire to
Neutral wire;
(connector)
(branch circuit wiring)
Green wire to
Ground wire or
(connector)
Ground system.
(branch circuit wiring)
3. Click Connector into PT Series GFCI.
4. Verify Connector security and
engagement.
TESTTEST
RESETRESET
TESTTEST
RESETRESET
TESTTEST
RESETRESET
Note: The Plugtail™ GFCI does not provide
protection to other receptacles/outlets.
Insert
5. Installation instructions:
6. Test your work
Verify
engagement