beautypg.com

Legrand L2EVSE30 Installation User Manual

Pass & seymour

background image

Pass & Seymour

®

Electric Vehicle Charging Station

Station de chargement pour véhicules électriques

Estación de carga de vehículo eléctrico

Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China

Catalog Number • Numéro de Catalogue • Le Numéro de Catalogue: L2EVSE30

Installation Instructions • Instrucciones de Instalación • Notice d’Installation

No: 341054 – 11/13

NOTES:
Read and understand all directions contained in

this document.
Observe all local electrical and building codes.
Make sure the wall structure is capable of supporting the

charging station.
Leave this installation document with the vehicle/home

owner.
INSTALLATION
The following tools are required for a wall mount installation of

the L2EVSE30 charging station:
• Wire cutters, level, drill with 1/8" bit, tape measure, pencil,

Phillips screwdriver, T30 Torx driver, slip joint pliers, wire

crimpers.

Additional equipment required (not included)
• copper supply cable (specified by NEC

®

)

• circuit breaker (specified by NEC)
• appropriate wall anchors (for studded wall or solid wall

installation)

• applicable flexible conduit and fittings
Note: a hole is provided in the wiring compartment that

will accept 1" NPT conduit fittings.
• (2) #10 x 2" wood screws
• eyelets for incoming power cables
LOCATING THE CHARGING STATION
The charging station should be mounted conveniently near the

electric vehicle (ev) parking location. The station is supplied

with an 18 ft. charging cord with a charge connector on the

end. This connector is intended to mate with the charging

port that is located on the electric vehicle. The charging

station should be mounted in a location where there is a clear,

unobstructed path to the vehicle charging port on the car. The

recommended mounting height for the charging unit is at least

18" but not more than 48" above the floor per NEC article 625.
INSTALLING THE CHARGING STATION
1. Remove the charger from packaging and identify the

charger mounting plate.

2. Locate a vertical wall stud where the charging station

will be mounted.

3. Measure up 52" from the floor surface and make a

horizontal pencil mark across the wall stud location.

4. Draw a vertical line that intersects the horizontal line on the

center of the stud. The intersection of these two lines will be

the location of the top hole for the charger mounting plate.

(Figure 2)

5. Using the mounting plate as a template, align the top hole

in the plate with the wall location created in step 4. Use the

plate as a template to locate the lower mounting hole.

6. For wood studs, drill 1/8" dia. mounting holes 2" deep at

the locations indicated by the plate. For metal studs or

solid walls which require anchors, refer to manufacturer’s

instructions for anchor installation.

7. Align mounting plate on wall and install wood screws

through plate into wall. For metal studs or solid wall, use

the hardware supplied with the anchors and follow the

manufacturer’s instructions for anchoring the plate to

the wall.

8. Mount the charger hook conveniently on the wall below the

charger with appropriate fasteners.

Advance to the next section: “WIRING THE CHARGING

STATION” before attaching the charger to the mounting plate.
WIRING THE CHARGING STATION
WARNING:
Improper wiring of any electrical wiring device can

cause serious injury or death. These wiring devices should

be installed only by an electrician or other qualified person in

accordance with all appropriate codes and standards. If you

are not sure about any part of these instructions, consult a

qualified electrician.
WARNING: To avoid risk of fire or shock which may result

in serious injury or death, turn off power to outlet box using

breaker or fuse at the service entrance. Before wiring, verify

that power has been removed by testing with a circuit tester at

the outlet box.
CAUTION: This device is for use only with copper or copper

clad wire. Do not use this device with aluminum wire.
1. Install a dedicated, 240VAC or 208VAC, 60Hz, grounded

branch circuit with a 40A circuit breaker or fuse. This circuit

should comply with the NEC and any local codes that

apply. The circuit must reach the entry port on the charger

and have a minimum of 12" of extra wire to terminate inside

the charger.

2. Remove 4 screws and cover from back of charger to access

wiring chamber.

3. Install and secure appropriate watertight bushing into hole

provided. (Hole is provided for 1" NPT fitting)

4. Feed incoming power conductors through bushing, strip

insulation, and securely crimp appropriate eyelet to the end

of each conductor. (Figure 3.)

5. Secure conductors under screw heads and torque to 17.7

lb/in (2.0 N-m).

6. Replace cover on wiring chamber and tighten 4 screws.
7. Align charger to mounting plate and secure with 3 screws

provided. (Figure 4.)

8. Close circuit breaker or fuse to energize the charger.
9. Verify the correct installation of the charger by reviewing the

indicator light panel. A solid green light means the charger

is ready to charge. For any other than solid green, see the

status indicator display located in the user guide.

INSTRUCTIONS PERTAINING TO THE RISK OF

ELECTRIC SHOCK
This product should be supervised when used around children.
Do not put fingers into the electric vehicle connector.
Do not use this product if the flexible power cord or EV cable is

frayed, have broken insulation, or any other signs of damage.
Do not use this product if the enclosure or the EV connector

is broken, cracked, open or show any other indication of

damage.
CAUTION: To reduce the risk of fire, connect only to a circuit

provided with 40 amperes maximum branch circuit overcurrent

protection in accordance with the National Electrical Code,

ANSI/NFPA 70.

READ ALL INSTRUCTIONS BEFORE
BEGINNING
The Legrand/Pass & Seymour catalog

number L2EVSE30 should be connected

only to a 240VAC or 208VAC, 60Hz,

grounded branch circuit and its

installation must comply with the NEC

and any local codes or regulations.
Installation of the Legrand/Pass &

Seymour catalog number L2EVSE30

must be performed by a licensed

electrician.
Shock, fire, property damage, personal

injury, or death may result if these

instructions are not followed.
If you have any questions about the use

or installation of this product, contact

your Legrand/Pass & Seymour technical

support representative at: 800-223-4185

(or [email protected]).

There are no user serviceable parts

contained in this product. Any attempt to

service this prod uct may result in shock

or fire causing property damage,

personal injury,

or death.
Save these instructions for future

reference.

LISEZ TOUTES LES INSTRUCTIONS

AVANT DE COMMENCER
La référence catalogue Legrand/

Pass & Seymour L2EVSE30 doit être

uniquement raccordée à un circuit de

dérivation en 240 V CA ou 208 V CA, 60

Hz, raccordé à la terre ; l’installation doit

être conforme aux normes NEC ainsi

qu’aux réglementations et lois locales.
L’installation de la référence catalogue

Legrand/Pass & Seymour L2EVSE30

doit être effectuée par un électricien

agréé.
Dans le cas contraire, il peut en résulter

une électrocution, un incendie, des

dommages au niveau de l’équipement,

des blessures graves voire mortelles.
Si vous avez la moindre question

concernant l’utilisation ou l’installation de

ce produit, contactez votre représentant

technique Legrand/Pass & Seymour au :

800-223-4185 (ou par courriel à tech_

[email protected]). Ce produit

ne contient aucune pièce pouvant être

réparée par l’utilisateur. Toute tentative

d’entretien de ce produit peut conduire

à une électrocution ou à un incendie

provoquant des dommages au niveau de

l’équipement, des blessures graves voire

mortelles.
Conservez ces instructions pour pouvoir

les consulter ultérieurement.

LEA TODAS LAS INSTRUCCIONES

ANTES DE COMENZAR
El número de catálogo L2EVSE30

de Legrand/Pass & Seymour debe

conectarse únicamente a un circuito

derivado a tierra de 240 V CC o a

208 V CC de 60Hz, y su instalación

debe cumplir con los códigos NEC

y cualquier otros códigos locales o

reglamentaciones.
La instalación del número de catálogo

L2EVSE30 de Legrand/Pass & Seymour

debe ser realizada por un electricista

autorizado.
Si no se siguen estas instrucciones,

se puede provocar choque, incendio,

daños materiales, lesiones personales

o muerte.
Si tiene preguntas acerca del uso o la

instalación de este producto, contáctese

con su representante de asistencia

técnica de Legrand/Pass & Seymour

al teléfono: 800-223-4185 (o tech_

[email protected]). No hay

piezas que puedan ser reparadas por

el usuario en este producto. Cualquier

intento de reparar este producto, puede

provocar choque o incendio que cause

daños materiales, lesiones personales

o muerte.
Guarde estas instrucciones para

referencia futura.

Figure / Illustration / Figura 3

Figure / Illustration / Figura 1

Figure / Illustration / Figura 4

Figure / Illustration / Figura 2

52"