beautypg.com

Legrand VA Trenchduct Flush Floor Feeder System 485 Cover Lifter Usage User Manual

485 cover plate lifter

background image

485 Cover Plate Lifter

I N S T A L L A T I O N I N S T R U C T I O N S

Installation Instruction No.: 1 005 238 – August 2006

Wiremold / Legrand electrical systems conform to and should
be properly grounded in compliance with requirements of the current
National Electrical Code or codes administered by local authorities.

All electrical products may present a possible shock or fire
hazard if improperly installed or used. Wiremold / Legrand electrical
products may bear the mark as UL Listed and/or Classified and
should be installed in conformance with current local and/or the
National Electrical Code.

IMPORTANT: Please read all instructions

before beginning.

NOTE: The 485 Cover Plate Lifter is intended for lifting cover plates only. The surface

of the cover plate must be clean, smooth, dry, and free of oil and grease.

75 lbs. Maximum Weight

Detaching Lever

1. Remove screws from cover plates.

2. Place cover plate lifter on the center of the cover plate. Gently squeeze the detaching lever while applying

pressure to the cover plate lifter, assuring that it will seat itself properly. Once cups are seated, release
pressure on detaching lever prior to releasing pressure to lifter. Do not apply pressure to the detaching lever
once it has been properly seated against surface of the cover plate. Watch the cups for 10 seconds. The
cups are properly seated if you do not see them rise upward within 10 seconds after applying pressure. If
there is no vacuum seal, first inspect the vacuum cups to see if there is a tear or there is debris (even
something as small as a metal shaving or cardboard debris) anywhere on the cup that could prevent the seal.

3. Lift cover plate in a horizontal position and store in desired location.

4. To release lifter from cover plate, lift up gently on the detaching lever with your fingers while the palm of your

hand is placed upon the top handle. Lifting up on the detaching lever with too much force can cause it to
bend which reduces the effectiveness of the lifter.

NOTE: The carrying capacity of this lifter is 75 lbs. (34 kg). This rating is based on application to clean, dry,

smooth metal at an ambient temperature of 20° C after generating the maximum vacuum.

To assure the safest possible use, see the safety rules on the next page: