Step 1 Remove cover. Remove clamps
that hold in wireway. Withdraw
wireway from pole – do not
remove entrance end fitting.
Step 2 Determine length “A” to be
removed from pole. Fold wires
back and cut length “A” from
shown ends of cover, base,
and wireway.
Step 3 To re-assemble – Replace
wireway into the base with
conductors inside. Replace
and tighten down clamps.
Snap cover onto pole.
Cover
Wireway
Base
Clamp
Length
“A”
Clamp
Entrance
End Fitting
TO SHORTEN ALTP POWER POLE
BEFORE INSTALLATION:
Length
“A”
Length
“A”
NOTE: Tele-Power Pole must extend above hanger