beautypg.com

Legrand NP800 Series User Manual

Np800 series, Jumbo tele-power, Pole

background image

NP800 Series

Jumbo Tele-Power

®

Pole

I N S TA L L AT I O N I N S T R U C T I O N S

Installation Instruction No.: INS00006R1 – Updated April 2005

Wiremold Electrical Systems conform to and should be
installed and properly grounded in compliance with
requirements of the current National Electrical Code, Canadian
Electrical Code or codes administered by local authorities.

All electrical products may represent possible shock or fire
hazard if improperly installed or used. Wiremold electrical
products are UL Listed to U.S. and Canadian safety
standards, made for interior use only, and should be installed
in conformance with current local and/or the National
Electrical Code.

NP800 Series Tele-Power Poles are provided standard with an anodized aluminum finish or may be painted any number of color

selected from a full array of powder coat finishes. Standard poles have two channels of different depths. These channels may be
divided at various locations by snap-in dividers to form additional channels. All channels may enclose either power or
communication wiring. Wire fill capacities are outlined below, followed by illustrations of standard pole hardware, and instructions
for a typical installation (over). Poles may be supplied with box ends of various sizes. Walkerflex™ Manufactured Wiring System
Connectors or with 10' [3.04m] cord ends (cUL only).

CABLE TYPE

UNSHIELDED TWISTED PAIR

SHIELDED TWISTED PAIR

COAX

TWINAX

DESCRIPTION

CAT 3

CAT3

CAT5e

CAT5

CAT6

TYPE 1

TYPE 2

TYPE 9

RG58/U

RG59/U

RG62

RG6U

100 OHM

4 PAIR

25 PAIR

4 PAIR

25 PAIR

4 PAIR

22 AWG

22 AWG

22 AWG

20 AWG

22 AWG

22 AWG

18 AWG

NOMINAL O.D. (In.)

0.19

0.36

0.21

0.337

0.25

0.39

0.465

0.275

0.195

0.242

0.242

0.27

0.24

2.4

25.0

7.0

20.0

8.0

14.0

6.0

4.0

12.0

24.0

15.0

15.0

12.0

15.0

2.8

29.0

8.0

24.0

9.0

17.0

7.0

4.0

14.0

28.0

18.0

18.0

14.0

18.0

3.2

33.0

9.0

27.0

10.0

19.0

8.0

5.0

16.0

32.0

20.0

20.0

16.0

21.0

4.2

44.0

12.0

36.0

14.0

25.0

10.0

7.0

21.0

42.0

27.0

27.0

22.0

27.0

4.3

45.0

12.0

37.0

14.0

26.0

10.0

7.0

21.0

43.0

28.0

28.0

22.0

28.0

4.8

50.0

14.0

41.0

16.0

29.0

12.0

8.0

24.0

48.0

31.0

31.0

25.0

31.0

5

52.0

14.0

43.0

16.0

30.0

12.0

8.0

25.0

50.0

32.0

32.0

26.0

33.0

5.2

55.0

15.0

45.0

17.0

31.0

13.0

9.0

26.0

52.0

33.0

33.0

27.0

34.0

5.8

61.0

17.0

50.0

19.0

35.0

14.0

10.0

29.0

58.0

37.0

37.0

30.0

38.0

6.2

65.0

18.0

53.0

20.0

37.0

15.0

10.0

31.0

62.0

40.0

40.0

32.0

41.0

7

74.0

20.0

60.0

23.0

42.0

17.0

12.0

35.0

70.0

45.0

45.0

36.0

46.0

7.7

81.0

22.0

66.0

25.0

47.0

19.0

13.0

38.0

77.0

50.0

50.0

40.0

51.0

8

84.0

23.0

69.0

26.0

48.0

20.0

14.0

40.0

80.0

52.0

52.0

41.0

52.0

12

126.0

35.0

103.0

40.0

73.0

30.0

21.0

60.0

120.0

78.0

78.0

62.0

79.0

DATA/COMMUNICATION: MAXIMUM WIRE FILLS FOR UL AND cUL LISTED TELE-POWER POLES

CAPACITY OF CROSS SECTION (In

2

)

SNAP-IN DIVIDERS AREAS OF CROSS SECTIONS

Large Compartment

Small Compartment

5"

[127mm]

2 13/16"

[71mm]

12 sq. in.

[7742mm

2

]

1 5/8"

[41mm]

4.3" sq. in.
[2774mm

2

]

7.7 sq. in.

[4698mm

2

]

2 3/16"

[71mm]

5.8" sq. in.
[3742mm

2

]

6.2 sq. in.

[4000mm

2

]

3 1/8"

[79mm]

5" sq. in.

[3226mm

2

]

7 sq. in.

[4516mm

2

]

1 5/8"

[41mm]

3.4" sq. in.
[2194mm

2

]

4.3 sq. in.

[2774mm

2

]

5"

[127mm]

1 15/16"

[49mm]

8 sq. in.

[5161mm

2

]

1 5/8"

[41mm]

2.8" sq. in.
[1806mm

2

]

5.2 sq. in.

[3355mm

2

]

2 3/16"

[71mm]

3.8" sq. in.
[2452mm

2

]

4.2 sq. in.

[2710mm

2

]

3 1/8"

[79mm]

3.2" sq. in.
[2065mm

2

]

4.8 sq. in.

[3097mm

2

]

1 5/8"

[41mm]

2.4" sq. in.
[1548mm

2

]

2.8 sq. in.

[1806mm

2

]

NOTE: Capacity range is calculated at 30% of raceway areas as stated in the Commercial Buildings Standard for Telecommunication Pathways

and Spaces, EIA/TIA-569.
These are the approximate diameter and cross-sectional areas for typical cables in each category. Check with the cable manufacturer for
more accurate dimensions.