beautypg.com

Legrand E77378WHT3WB User Manual

Page 2

background image

1. Attach Pole Brace to pole using 3/8" threaded rod

(not supplied). Secure with appropriate nuts; do not
tighten. Attach Wireduct Bracket to Wireduct. Secure
the opposite end of the threaded rod to the Wireduct
with suitable nuts. For security, double nutting at the
Wireduct end is recommended. Tighten all nuts after
checking that the pole is plumb.

CAUTION: Distance between pole and Wireduct
must not exceed 36".

2. Wireduct Power Wiring.

Run branch circuit conductors through
the Wireduct in an approved manner.
Install the modular whip connector in
1/2" KO in cover of Wireduct nearest
the pole. Working from the inside of the
Wireduct with cover open, hook the
mounting clip on the lower edge of the
hole cut. Tilt and push the receptacle
face into hole cut using a straight blade
screwdriver to compress and seat the
top of mounting clip.

Connect the whip connector pigtail
leads to the branch circuit conductors
using an approved method and carefully
observing color coding. Connect green
ground wire to ground screw in pull box.
Compress locking tabs on power whip
plug and insert into appropriate Wireduct
receptacles. Receptacle and plug with
the orange dot indicate isolated ground.

3. Additional Mounting Method for

securing pole to register counter
Erect pole at desired location. Align for
(4) holes in “U” shaped bracket with
matching holes in the counter vertical
member. Secure with appropriate
fasteners (not provided)

This manual is related to the following products: