IHSE USA 234 Series VTO2/VRO2 KVM-Extender User Manual
Page 22

VTO2/VRO2 V.6.00 –5 STRAND KVM-EXTENDER
22
The location of the 7- Segment display is shown below:
7-Segment display on VTO2/VRO2 Extender
7-Segment
display
Diagnostics
Possible cause of fault
Only in mode “AGC-ON”
NO error
NO error detectable
Only in mode “AGC-ON”
illuminated
NO error detectable:
Processor adjusts color amplifying (AGC)
Blank-pulse is missing
Problem with the GREEN fibre
Data interface (receiving)
deranged
Problem with the 1-Fibre
Problem with the Local Unit
1-Fibre and 2-Fibre swapped
Contrast is adjusted too high
The gain of the contrast potentiometer is
adjusted too high. Automatic Gain Control
(AGC) is no longer possible. Please re-
adjust to lower gain.
HSYNC signal is missing
Problem with the GREEN fibre
Problem with the CPU cables
Wrong jumper setting in the Local unit
VSYNC signal is missing
Problem with the BLUE fibre
Problem with the CPU cables
Wrong jumper setting in the local unit
7-Segment display for troubleshooting