In this example:

DA79 is the serial ID of the digitiser.

Z0, N0, E0 correspond to input channels Z, N, and E, output

through Tap 0.

Z4, N4, E4 correspond to input channels Z, N, and E, output

through Tap 2. A six-channel digitiser connected to two triaxial

instruments will use Z0, N0, E0, Z1, N1, E1 for tap 0; Z2, N2, E2,

Z3, N3, E3 for tap 1; Z4, N4, E4, Z5, N5, E5 for tap 2; and Z6, N6,
E6, Z7, N7, E7 for tap 3. The digitiser in the example has only one

triaxial instrument connected to it, so Z/N/E1, 3, 5 and 7 are

unused.

You can change these designations if you wish: see the Scream!

manual or online help for more details.

00 is the digitiser status stream (notice: no sample rate),

M8, M9, MA are slow-rate Mux channels reporting the sensor

mass positions for the Z, N, and E components (

“Mux Channels”

in Section 3.1

).

ME is another Mux channel, here used for reporting the

temperature.