Guntermann & Drunck CATCenter X systems Communicaton modules User Manual
Page 17
Guntermann & Drunck GmbH CATCenter Communication Components
Page 17
2.4.2 GET
Function
2.4.2.1 Getting Screen Contents
Access the GET submenu by pressing the key
F8
in the SELECT menu. The
consoles (source consoles) from which you can pull the screen contents to
your own console (target console) are shown here. Your own console is not
included in this list.
G e t t a r g e t
C o n s o l e T a r g e t
CON 00303047
CPU-ID 00000209
CON 00001047
not connected
CON 00007477
no target right
CON 00056940
CPU-ID 00020685
F3: Refresh
ESC : Select
ENTER: Get
The following keys are available to you in this menu:
•
F3
key: Refresh the contents of this window
•
ESC
key: Returns to the SELECT menu
•
ENTER
key: Manually select the console as the source
of the get function and initiate the Get function
This menu displays the following information:
CON 00303047
CPU-ID 00000209
Console you can pull screen
contents from (the name
can be edited, see
Chapter
5.6.1 of the CCX
Operation Guide
)
Physical name of a target being
accessed from this console.