C35553 Rev. 0167

NOTE: If a C06757 surge protector already exists (see pedestal left side view for location), skip Step 8 and proceed
with Step 9. Keep surge protector supplied in kit as a spare.

8.

While facing the terminal block/bracket assembly, with TB2 on it, locate an unused captive nut in the sheet metal
(several inches below and to the right). Install the C06757 surge protector using a C04037 screw and 068842
lockwasher. Terminate the green/yellow wire from the surge protector to Ground of TB2 and the black wires from the
surge protector to Hot and Neutral on TB2.

9.

For pump wiring to the Pump Control Unit, refer to the Islander II Installation Manual C35963. Once wiring is complete
and verified, re-connect the AC power to the Islander. Switch on AC power to the Islander and PCU power supply. After
wiring has been completed and tested, replace pedestal side covers.