Software requirements, System parameters – Gasboy EFS Trking Fuel Mgmnt User Manual
Page 4

Software Requirements
© 2007 GASBOY
7300 West Friendly Avenue · Post Office Box 22087
Greensboro, North Carolina 27420
Phone 1-800-444-5529 ·
· Printed in the U.S.A.
MDE-4644 Generic Host Configuration Instructions for EFS Trucking Fuel Management Systems · March 2007
Software Requirements
The following table lists the software requirements for the configuration.
System Parameters
Configure the following system parameters to include the values listed below.
For the following modem types, the parameter "Additional Hayes remote port command(s)"
needs to be configured with the value indicated.
Software
Version
SC II and Islander II Systems
V2.3K or above
SC III Systems
V3.4K or above
System Parameter
Description
Value
Sys_par page 4
Use remote verification (reader)
Savings Checking Credit
Sys_par page 4
Reader default payment
Credit
Sys_par page 5
Use remote verification (console)
Savings Checking Credit
Sys_par page 8
Remote port baud rate
1200*
Sys_par page 8
Remote port modem type**
2 with 20 second wait for carrier
Sys_par page 8***
Verification time out (CFN host)
45
Sys_par page 8
Send requests to host handler
None
Sys_par page 11
Always request dollars from CFN host
Savings Checking Credit
Sys_par page 11
Send transactions to CFN host
Savings Checking Credit
* - For Site/Islander II, the baud rate is set via switches (DSW2 position 3 - Closed, 4 - Open).
** - For Site/Islander II, the parameter is “Remote CFN port type”.
*** - For Site/Islander II, this parameter is on page 11.
System Parameter Modem Type
Value
Sys_par page 8
Zoom Faxmodem 56Kx Dual mode (white case)- Models 2948L, 2949L \N1%C0S37=5%K0
Zoom V.90 Faxmodem (black case): Model 2948C
\N1%C0&K0+MS=1
GASBOY Quick Connect Network Modem - Multitech Model
MT2834ZDXb
$MB1200