Software Requirements

The following table lists the software requirements for the configuration.

System Parameters

Configure the following system parameters to include the values listed below.

For the following modem types, the parameter "Additional Hayes remote port command(s)"
needs to be configured with the value indicated.

Software

Version

SC II and Islander II Systems

V2.3K or above

SC III Systems

V3.4K or above

System Parameter

Description

Value

Sys_par page 4

Use remote verification (reader)

Savings Checking Credit

Sys_par page 4

Reader default payment

Credit

Sys_par page 5

Use remote verification (console)

Savings Checking Credit

Sys_par page 8

Remote port baud rate

1200*

Sys_par page 8

Remote port modem type**

2 with 20 second wait for carrier

Sys_par page 8***

Verification time out (CFN host)

45

Sys_par page 8

Send requests to host handler

None

Sys_par page 11

Always request dollars from CFN host

Savings Checking Credit

Sys_par page 11

Send transactions to CFN host

Savings Checking Credit

* - For Site/Islander II, the baud rate is set via switches (DSW2 position 3 - Closed, 4 - Open).
** - For Site/Islander II, the parameter is “Remote CFN port type”.
*** - For Site/Islander II, this parameter is on page 11.

System Parameter Modem Type

Value

Sys_par page 8

Zoom Faxmodem 56Kx Dual mode (white case)- Models 2948L, 2949L \N1%C0S37=5%K0

Zoom V.90 Faxmodem (black case): Model 2948C

\N1%C0&K0+MS=1

GASBOY Quick Connect Network Modem - Multitech Model
MT2834ZDXb

$MB1200