Gasboy ME-800 SHM User Manual
Gasboy Hardware

C35588
Rev. 5034
INSTALLATION GUIDELINES - ME800 SHORT HAUL MODEM
The Series 1000 System can be wired for direct communication distances over 1500 feet using
ME800 asynchronous Short Haul Modems (SHM). One SHM is required for each end of the
communication line. Communication can be through Port 1 (as shown) or Port 2 of the Series
1000 system.
It is recommended that a surge protection device (P/N C08159) be purchased for each SHM to
help protect it from transient voltages that can be induced into the communication lines. One
device is required for each SHM.
This mounting kit C05795, for the ME800 Short Haul Modem, provides a shelf and all the
necessary interconnect cables required for installation of the SHM into the Series 1000 post. It
consists of the following:
C01168
Screw, 8-32 x 3/8
C02188
Bushing, Snap-in 5/8 ID
C35026
Bracket, SH Modem Mounting
C04660
Cable Assy., AC Power Receptacle
C04661
Cable Assy., RS-232 x 2' w/Spades
C34856
Instructions, Installation
C04371
Trim Material, Edge
C35588
Installation Guidelines - ME800 Short Haul Modem
Install the SHMs and surge protectors per the drawing and specifications listed below.
All wiring is to be installed and used in accordance with local building/fire codes, all Federal, State,
and Local codes, the National Electrical Code (NFPA 70), NFPA 30, and the Automotive and
Marine Service Station Code (NFPA 30A) codes and regulations. Canadian users must also
comply with the Canadian Electrical Code.
See opposite side of this sheet for wiring notes.