Gasboy Vapor Recovery Kit User Manual
Gasboy Hardware
![background image](https://www.manualsdir.com/files/787363/content/doc001.png)
032627 Rev. 0096
Page 1
VAPOR RECOVERY KIT INSTALLATION INSTRUCTIONS
FOR MODEL 9120
This instruction sheet covers the installation of the Model 9120, Vapor Recovery Kit (P/N 032628). Vapor recovery kit
does not include high hose retriever, hose, nozzle, swivel, and breakaway). You should have received the following:
Item
Qty.
P/N
Description
1
1
042741
Discharge Assembly
2
1
041605
Panel, Right Side (VR)
3
1
028934
Grommet
4
1
003317
Boot, Nozzle (VR)
5
2
052857
Bolt 8-32 x 5/8
6
1
003719
Hook, Nozzle (VR)
Item
Qty.
P/N
Description
7
1
049013
O-Ring
8
2
051805
Bolt 1/4-20 x 5/8
9
2
068891
Washer-Lock ¼
N/A
1
032627
Instruction Sheet
N/A
1
035282
Warning Sheet
Important: Read all instructions before beginning installation. Also, read and follow all precautions
regarding remote dispensers and pumps on the Warnings and Safeguards sheet, 035282, included in this
kit. Before performing any work which may produce sparks (e.g. drilling, use of power tools, etc.), remove
dispenser a safe distance from any flammable materials.
Installing Right Side Panel
1.
Remove front door panel (key required).
2.
Remove bezel assembly by unfastening two (2) Phillips head screws.
3.
Remove rear door panel (key required).
4.
Remove three (3) Phillips head screws and remove rear access panel.
5.
Remove discharge pipe elbow.
6.
Remove six (6) nuts from top cover assembly and remove top cover.
7.
Remove three (3) screws from right side panel. Remove right side panel and discard.
8.
Assemble new right side panel (item 2) with three (3) screws from Step 7.
Installing Discharge Assembly
9.
Remove two (2) 5/16-18 bolts from discharge casting
and two (2) 1/4-20 bolts from discharge clamp.
Remove discharge assembly from unit. NOTE:
Replace O-ring with supplied (item 7) O-ring. Apply
lithium based grease to O-ring.
10. Install new vapor recovery discharge assembly by
reinstalling two (2) 5/16-18 bolts and two (2) 1/4-20
bolts from Step 9. NOTE: 1/4-20 bolts will secure
vapor recovery bracket to platform assembly.
11. Remove two (2) 8-32 screws from nozzle boot
casting and remove. Install vapor recovery nozzle
boot (item 4) with same screws.
12. Remove two (2) 1/4-20 bolts from nozzle hook
assembly and remove nozzle hook. Install vapor
recovery nozzle hook (item 6) with same 1/4-20
bolts.
13. Reinstall the dispenser top cover and panels by
following Steps 6 through 1.