beautypg.com

Gasboy Electric Keytrol User Manual

Page 36

background image

GASBOY Electric Keytrol

6-4

03/28/03


l

Mount new counter with the same two bolts or bolts provided with the new counter.

Counters are 24 VDC (Record reading).


l

Solder leads to same turret terminals from which the old counter was removed.


l

Re-bolt PCB with four bolts.


3. If all the counters on one module strip do not function, while those on another adjacent

module do, check all four spade terminal connections for breakage or loose terminal block
screws.


4.

If none of the counters are functioning, the problem may be with the pulser, 24 VDC power
supply or interwiring.


KEYSWITCH (Microswitch: P/N 0M0011, includes tumbler)


1. Keyswitches can be isolated as the source of error as described in section Counter or

Totalizer.


2. If the keyswitch turns (physically) but does not actuate the rear-mounted microswitch, as

determined above, it is not necessary to remove the tumbler mechanism from the frame.
Also, it may be desirable to leave the same tumbler mechanism to avoid having to issue new
keys.


3. To remove the rear-mounted microswitch, remove PCB as described in Counter or

Totalizer, Step 2. Unscrew 2 bolts holding the microswitch to the rear of the key mechanism.
CAUTION! DO NOT LOSE THESE SCREWS!


4.

Mark lead orientation and unsolder, or pull off.


5.

Solder new leads in same configuration as removed, or push on.


6. Rebolt

microswitch.


7. Rebolt

PCB.


KEYSWITCH (Tumbler: P/N 0M0011, includes microswitch)


1.

To change lock mechanism it is not necessary to remove or unsolder the microswitch.


2.

Remove 2 bolts holding microswitch to rear of key mechanism.


3.

Remove nut holding switch tumbler to frame. Remove tumbler mechanism.


4.

Install new key lock tumbler and tighten nut.


5. Rebolt

microswitch.


6. Rebolt

PCB.


7.

Issue new key(s) to proper personnel.