Preventive Maintenance
Preventive Maintenance
Change the Filter
If the unit is equipped with a filter, check and change it at regular intervals. A dirty filter in a
pump will cause a slower delivery rate. Refer to the accessories section of your parts manual to
ensure that you replace the filter with one designed for your model. Always use a drip pan
directly below the filter when removing the cartridge to prevent contamination of the soil and
to aid in fluid recovery. Refer to item 2 in the parts list under
on
Power Reset External Adjustment
If the pump or remote dispenser fails to reset or shut off properly, the reset motor may need to
be adjusted. To adjust, proceed as follows:
1
Loosen the lock nut on the adjusting screw and back screw out until it stops.
2
Move the reset lever to the ON position.
3
Turn adjustment screw in until reset motor starts.
4
Advance adjustment screw an additional 1/2 to 3/4 turn. Hold screw in this position and
tighten the lock nut.
5
Move the reset lever to the OFF position, and then back to the ON position to verify if the reset
motor operates properly. The reset coupling should make one revolution and stop.
Adjustment Screw
Lock Nut