Function Code 22:
Reported Volume Decimal Point
0 = XXX.XXX***
1 = XXXX.XX (export only)

Function Code 24:
Hose Pressurization
0 = Off***
1 = 2 hours
2 = 1/2 hours
Note: Not available in U.S. gallons

configuration.

Command Code 12:
Pump Program
• Enter 12
• Enter Side #

1 = Side 1
2 = Side 2

• Enter Function Code (1-4)
• Enter Configuration Code

Function Code 1:
Two-Wire Pump ID
1-16 = (7*** for Side 1; 11*** for Side 2)

Function Code 3:
Side Exists
0 = Does not exist
1 = Exists***

Function Code 4:
PPU Options
0 = Level 1 price bar displays level

sent by console or Card Reader
IN Dispenser (CRIND

®

)***

1 = Normal

*** Default
† Must be programmed to ‘1’ in New

Jersey.

From Level 3

Command Code 13:
PIN Code Change
Press Enter after selections.
• Enter 13
• Enter Level # 1, 2, or 3
• Enter new PIN Code
Unit returns to Command Input Mode.

Command Code 15:
Function Code 1:
Preselect Time-Out
0 - 999 seconds

Function Code 2:
Pump Time Out
0 - 999 seconds

Function Code 3:
Beeper Time Out
0 - 999 seconds

Function Code 4:
Slowdown Valve
0 - 0.999 gallons

Command Code 17
Conversion Factor and Master
Reset
Select Function Code.

Function Code 1:
Conversion Factor
0 = No conversion factor***
1 = U.S. Gallons
2 = Imperial Gallons
3 = Liters

Function Code 2:
Master Reset (Retains Totals)
0 = No Master Reset
1 = Master Reset

Command Code 18:
Pulse Output Configuration
• Enter 18
• Enter Function #
• Enter Configuration #

Function Code 1:
Volume PPU
1. 1 PPU
2. 10 PPU***
3. 50 PPU
4. 100 PPU
5. 1000 PPU

Function Code 2:
Volume Pulse Width
1. 0.5 ms
2. 1.0 ms
3. 2.0 ms
4. 4.0 ms***
5. 17.0 ms
6. 19.0 ms
7. 26.0 ms
8. 150.0 ms

Function Code 3:
Money Pulse Width
1. 0.5 ms
2. 1.0 ms
3. 2.0 ms
4. 4.0 ms***
5. 17.0 ms
6. 19.0 ms
7. 26.0 ms

Function Code 4:
Volume Suppression (at start of
sale)
1. 0.030***
2. 0.009
3. 0.000

Function Code 5:
Quadrature Pulse Option
0 = Disabled***
1 = Enabled

Function Code 6:
Authorize After Pump Stop
0 = Disabled***
1 = Enabled

Function Code 7:
Price Restore Option
0 = Disabled***
1 = Enabled

*** Default

ATC Programming

• Turn ON the programming switch on

the ATC Controller board.

• Press 100 then Enter.
• Select Fuel Type and press Enter.

740 = Gasoline
840 = Diesel
730 = Default

• Firmware cycles through each

fueling position. Select Fuel Type
and press Enter.

• Turn OFF the programming switch

on the ATC Controller board.

• Press F2 to exit ATC Programming

Mode.

ATC Inspection
Modes

• From Manager Keypad, press an

ATC Function Code (see below)
when unit is idle.

• Press Enter and Meter Number, if

appropriate.

• Press F1 to exit ATC Inspection

Mode.

Function Code 200:
Real Time Transaction Mode
• Main Display = Gross Volume
• Volume Display = Net Volume
• Grade 1 PPU Display = Current

Temperature

Function Code 300:
Audit Last Transaction
• Main Display = Gross Volume
• Volume Display = Net Volume
• Grade 1 PPU Display = Average

Temperature

Function Code 301:
Display Volume Correction Factor
• Main Display = Meter Number
• Grade 1 PPU Display = Volume

Correction Factor

Function Code 302:
Display Fuel Density
• Main Display = Meter Number
• Grade 1 PPU Display = 730 Gas or

840 Diesel

Function Code 303:Display
Temperature
• Main Display = Meter Number
• Grade 1 PPU Display = Current

Temperature

Function Code 304:
Display Gross Totals
• Volume Display = Gross Volume

(most significant)

• Grade 1 PPU Display = Gross

Volume (least significant)

Function Code 500:
Display Software Version
Main Display = ATC Version

Error Codes

Code

Description

20

Pulser Fail

24

Conversion Factor Changed/Not
Programmed

25

Two-Wire/Standalone Mode
Changed

26

Meter Not Calibrated

27

Side 1 Two-Wire ID Changed

28

Side 2 Two-Wire ID Changed

29

Pump Time-Out Error

31

Totals Data Error

32

Pulser Count Error

35

Configuration Data Error

36

Unit Type Configuration Code
Changed

37

PIN Code 1 Changed

38

PIN Code 2 Changed

39

Cash/Credit Option Changed

40

Master Reset Jumper in Place

41

Side Exists Option Changed

44

Pump Handle Up at Power Up

45

Preset Overrun (Minor)

46

Preset Overrun (Major)

Atlas