GAI-Tronics 300 Series RED ALERT Emergency Telephone Manual User Manual
Page 42

P
UB
.
42004-438K
300
S
ERIES
E
MERGENCY
T
ELEPHONE
M
ANUAL
P
AGE
40 of 45
f:\standard ioms - current release\42004 instr. manuals\42004-438k.doc
01/15
Table 13. Programming Documentation Table
Function
Key Sequence
Default
Settings
User Settings
Auto-dial or Ring-Down Programming (see Table 4 on page 33)
HELP Button Auto-dial Number 1
DD*1 *123456789*0#
HELP Button Auto-dial Number 2
DD*2
None
HELP Button Auto-dial Number 3
DD*3
None
CALL Button Auto-dial Number
DD*4 None
Primary Dial Tone Delay
#10NN 3
seconds
Secondary Line Dial Tone Delay
#11NN
2 seconds
Ring-down Operation
*1
None
Password Protection Feature Programming (see Table 5 on page 34)
Password Protection
#14NNNN 2468
Disconnect Options Programming (see Table 8 on page 36)
Emergency Push-button Disconnect
#17L 1
(enabled)
Call Time-out Disconnect
#12NN 10
minutes
Dial Tone Disconnect
#19L 0
(disabled)
ADA Programming (see Table 9 on page 37)
DTMF Disconnect Option
#18L #181
Identification Code Entry
#13LNNN None
Other Programming Features
Auto-Answer Alert Feature
(see Table 6 on page 34)
#16L 0
(disabled)
Off-Hook Ringing Feature
(see Table 7 on page 35)
#22L 0
(disabled)
Extended Strobe Operation
(see Table 10 on page 37)
#25NNN
0 0 0 (disabled)
Output 4 Control Setup
(see Table 11 on page 38)
NN…*8
#26NNN
90125
#26050 (5 sec.)
Early Microphone Option
(see Table 12 on page 39)
#71L 0
(disabled)
Table Legend
D = DTMF digit 0–9, *, or #
N = Numeric digit 0–9 L = 0-Disable, 1-Enable