P

UB

.

42004-438K

300

S

ERIES

E

MERGENCY

T

ELEPHONE

M

ANUAL

P

AGE

31 of 45

f:\standard ioms - current release\42004 instr. manuals\42004-438k.doc
01/15

Programming Sequence

The following command sequences are common to both “remote” and “local” programming and are used
to configure the telephone to the desired operating parameters.

1. Dial the factory-default password 2468 (or appropriate customer-selected password). A success tone

(short beep) is generated to indicate that “standard” programming mode has been accessed.

2. After hearing the password success tone, begin entering each desired programming key sequence.

Refer to the “Programming Sequences” section on page 31. A success tone (short beep) is generated
each time a new key sequence is accepted. An error tone (two low tones) is generated to indicate an
error. If an error tone is generated, verify the key sequence and enter the sequence again.

3. To terminate the programming call:

a. Remote – Place the programming telephone on hook. The RED ALERT

®

telephone will

automatically end the programming call within 20 seconds.

b. Local – Press the CALL or

HELP

push button (whichever is connected to J1) to end the call.

Restore any moved push-button harness connectors to their original position (if necessary).

N

OTES

:

1. The RED ALERT

®

telephone will automatically time out and disconnect if 20 seconds elapses

between digit entries, or if an invalid password is entered.

2. If DTMF digits have not been dialed within 3 seconds of the first success tone, the telephone will exit

programming mode and revert to a standard voice call.

3. If the password success tone is not generated, the telephone has failed to recognize the password.

Therefore, the telephone must then be programmed with the password disabled. Refer to the
“Password Disabled Programming” section on page 31.

Password Disabled Programming

The programmable features of the RED ALERT

®

Emergency Telephones are protected by a factory

default or user specified password, as previously described. Situations may arise when a setting change is
required but the password is forgotten or unknown. To permit continued programming support in this
situation, converting to Password Disable Programming may be necessary and is described as follows:

1. Access the telephone’s PCBA and disable the password protection feature by changing jumper J9 to

the “DIS” position.

2. Confirm the auto-answer feature is enabled (jumper J14 should be in the “EN” position).

3. Using a touch-tone telephone, call the RED ALERT

®

Telephone. The telephone will automatically

answer the call and will generate a splash tone (low to high sequence) followed by a success tone
(single beep).

4. Begin entering the desired key sequences as previously described, following steps 2 and 3 in the

“Programming Sequence” section on page 31.