beautypg.com

External power for -003 and -004 models, Connecting a model 530 series strobe – GAI-Tronics 300 Series RED ALERT Emergency Telephone Manual User Manual

Page 22

background image

P

UB

.

42004-438K

300

S

ERIES

E

MERGENCY

T

ELEPHONE

M

ANUAL

P

AGE

20 of 45

f:\standard ioms - current release\42004 instr. manuals\42004-438k.doc
01/15

External Power for -003 and -004 Models

The Plug-in Power Supply is used for operations below −4º F (−20º C) and requires 120 V ac input to
provide a 5 V dc output to the unit. The Plug-in Power Supply is provided with a connectorized, 4-foot
power cable that plugs into P17 on the telephone PCBA. Remove the jumper from P17 pins 3 and 4 and
insert to the adjacent header J18 when using the plug-in power supply. See Figure 23 on page 23 for
jumper locations.

N

OTE

: The external power supply provided with these models does not provide telephone line power for

communications. It simply activates a heater circuit to allow operation to −40 ºC.

Connecting a Model 530 Series Strobe

Figure 22 below shows a typical connection detail of the GAI-Tronics 530-001/531A Strobe (sold
separately).

Figure 22. (Model 398-00x is shown as an example)

Connection to Optional GAI-Tronics 530-001/531A Strobe