GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual
Page 45

Pub. 42004-392G
M
ODEL
LE200-RM
R
ACK
-M
OUNT
P
AGE
/P
ARTY
®
L
INE
E
XTENDER
P
AGE
43 of 56
e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14
Table 39. Main PCBA
Designator Type
Function
J1
RJ45 receptacle LVDS data “out”
J2
RJ45 receptacle LVDS data “in”
J3 DB-25
connector
Connect to J1 on Termination Connection Module via 25-pin ribbon
cable.
J4 DB-25
connector
Connect to J1 on Page/Party
®
Termination Connection Module via
25-pin ribbon cable.
P1 N/A
Not
installed
P2
Post header
No connection - used during production testing of PCBA
P3 N/A
Not
installed
P4
Post header
No connection - used during production testing of PCBA
P5
Jumper clip
Page line ground fault detector (enabled/disabled)
P6, P7
Jumper clip
Party line #5 off-hook detector (enabled/disabled)
P8, P9
Jumper clip
Party line #4 off-hook detector (enabled/disabled)
P10, P11
Jumper clip
Party line #3 off-hook detector (enabled/disabled)
P12, P13
Jumper clip
Party line #2 off-hook detector (enabled/disabled)
P14, P15
Jumper clip
Party line #1 off-hook detector (enabled/disabled)
P16
Terminal block Page line monitor output - Terminals 1 and 3
No connection - Terminal 2
P17, P18
Terminal block Power 48 V dc (+) - Terminal 1
Power 48 V dc (−) - Terminal 2
P19
Terminal block T1/E1 Data TX (ring) - Terminal 1
T1/E1 Data TX (tip) - Terminal 2
T1/E1 Data RX (ring) - Terminal 3
T1/E1 Data RX (tip) - Terminal 4
P20
Jumper clip
T1/E1 receive transformer center tap floating/grounded.
P21
Jumper clip
T1/E1 transmit transformer center tap floating/grounded.
PB1 Push-button
switch
Used to retrain the echo cancellation circuit.
SW1 Rotary
HEX
switch
Used for diagnostic purposes. Set to 0 during normal operation.