Table 34 outlines the function settings for DIP switch S3:
Table 34. Function Settings for DIP Switch S3
Function Setting
Jitter
Attenuator
Select
S3-1: ON; Place jitter attenuator on RCV side
S3-1: OFF; Place jitter attenuator on XMT side (default setting)
Remote
Management
S3-2: ON; Remote management enabled (only at the REMOTE end)
S3-2: OFF; Remote management disabled (only at the LOCAL end) (default setting)
Loopback
Selection
S3-3: ON; S3-4: ON; None (default setting)
S3-3: OFF; S3-4: ON; Local loopback
S3-3: ON; S3-4: OFF; Analog loopback
S3-3: OFF; S3-4: OFF; Remote loopback
Monitor/Boost
Mode
S3-5: ON; S3-6: ON; Normal operation (No boost) (default setting)
S3-5: OFF; S3-6 ON; 20 dB
S3-5: ON; S3-6 OFF; 26 dB
S3-5: OFF; S3-6 OFF; 32 dB
NRZ Selection
S3-7: ON; Disable NRZ (Required for Passive Mode) (default setting)
S3-7: OFF; Enable NRZ (Line Terminating Mode)
Fiber Type
S3-8: Factory configured; DO NOT CHANGE
S3-9: Factory configured; DO NOT CHANGE
S3-10: Factory configured; DO NOT CHANGE