GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual
Page 40

Pub. 42004-392G
M
ODEL
LE200-RM
R
ACK
-M
OUNT
P
AGE
/P
ARTY
®
L
INE
E
XTENDER
P
AGE
38 of 56
e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14
Table 33 below outlines the functions settings for DIP switch S2:
Table 33. Function Settings for DIP Switch S2
Function Setting
T1/E1 Selection
S2-1: OFF; T1 mode selected (default setting)
S2-1: ON; E1 mode selected
Receive
Equalizer Gain
Limit
E1
S2-2: ON; −12 dB Short Haul
S2-2: OFF; −43 dB Long Haul
T1
S2-2: ON; −36 dB Long Haul
S2-2: OFF; −30 dB Limited Long Haul (default setting)
Line Encoding
S2-3: ON; B8ZS or T1 or HDB3 for E1
S2-3: OFF; AMI (default setting)
Transmit LIU
Wave Shape
(Build-out)
E1
S2-4 S2-5 S2-6
ON
ON
ON
75 ohms
OFF
ON
ON
125 ohms
ON
ON
OFF
75 S ohms with High Return Loss
OFF
ON
OFF
125 S ohms with High Return Loss
T1
S2-4 S2-5 S2-6
ON
ON
ON
DSX-1 (0 to 133 feet) 0 dB CSU (default setting)
OFF
ON
ON
DSX-1 (133 to 266 feet)
ON
OFF
ON
DSX-1 (266 to 399 feet)
OFF
OFF
ON
DSX-1 (399 to 533 feet)
ON
ON
OFF
DSX-1 (533 to 655 feet)
OFF
ON
OFF
−7.5 dB CSU
ON
OFF
OFF
−15 dB CSU
OFF
OFF
OFF
−22.5 dB CSU
Receive LIU
Termination
S2-7: ON; S2-8: ON; Receive side termination disabled
S2-7: OFF; S2-8: ON; Receive side 120 ohms enabled
S2-7: ON; S2-8: OFF; Receive side 100 ohms enabled (default setting)
S2-7: OFF; S2-8: OFF; Receive side 75 ohms enabled
Transmit Data
Source
S2-9: ON; S2-10: ON; Standard data (default setting)
S2-9: OFF; S2-10: ON; Transmit pseudo-random bit sequence (PRBS)
S2-9: ON; S2-10: OFF; Transmit alternating ones and zeros
S2-9: OFF; S2-10: OFF; Transmit unframed all ones